Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Theoretical limits to sensitivity and resolution in magneto-acousto-electrical tomography
Date
2017-10-21
Author
GHALICHI, Elyar
Gençer, Nevzat Güneri
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
235
views
0
downloads
Cite This
In this study, the performance of magneto-acousto-electrical tomography (MAET) is investigated quantitatively by considering interrelations between its sensitivity, resolution and conductivity contrast. An analytical solution for the forward problem of MAET is derived for two-dimensional (2D) concentric bodies by the separation of variables method. The electric potential and the acoustic pressure are separated into their angular and radial components. The series coefficients for these solutions are obtained from their respective boundary conditions. The electric potential on the boundary is related to the acoustic boundary acceleration analytically. From this relation, a sensitivity expression is derived relating fractional change in conductivity contrast to fractional change in the measured electric potential. This expression is a function of the resolution and conductivity contrast of the imaging system. It also depends on the acoustic wave number and the dimensions of the body. The pair-wise relations between these parameters are presented. The sensitivity behavior of MAET is compared with applied current electrical impedance tomography and the improvements for small inhomogeneities are presented. For eccentric bodies, a modified expression for the sensitivity is obtained by conformal mapping. For arbitrary periodic boundary excitations, the sensitivity expressions for harmonic cases are combined to obtain a unified sensitivity expression.
Subject Keywords
Magneto-acousto-electrical tomography
,
Electrical impedance tomography
,
Analytical solutions
,
Separation of variables method
URI
https://hdl.handle.net/11511/46317
Journal
PHYSICS IN MEDICINE AND BIOLOGY
DOI
https://doi.org/10.1088/1361-6560/aa82a1
Collections
Department of Electrical and Electronics Engineering, Article
Suggestions
OpenMETU
Core
Theoretical limits and safety considerations for magneto-acousto electrical tomography
Ghalichi, Elyar; Gençer, Nevzat Güneri; Department of Electrical and Electronics Engineering (2017)
In this study, the performance of Magneto-Acousto-Electrical Tomography (MAET) method is investigated quantitatively by considering interrelations between its sensitivity, resolution and conductivity contrast. An analytical solution for the forward problem of MAET is derived for two-dimensional (2D) concentric bodies by Separation of Variables Method. The electric potential and the acoustic pressure are separated to their angular and radial components. The series coefficients for these solutions are obtaine...
Equipotential projection based magnetic resonance electrical impedance tomography (mr-eit) for high resolution conductivity imaging
Özdemir, Mahir Sinan; Eyüboğlu, Behçet Murat; Department of Electrical and Electronics Engineering (2003)
In this study, a direct reconstruction algorithm for Magnetic Resonance Electrical Impedance Tomography (MR-EIT) is proposed and experimentally implemented for high resolution true conductivity imaging. In MR-EIT, elec trical impedance tomography (EIT) and magnetic resonance imaging (MRI) are combined together. Current density measurements are obtained making use of Magnetic Resonance Current Density Imaging (MR-CDI) techniques and peripheral potential measurements are determined using conventional EIT tech...
Experimental investigation of residual stresses introduced via shot peening and their effect on fatigue life of ball bearings
Küçükyılmaz, Ali; Gür, Cemil Hakan; Department of Metallurgical and Materials Engineering (2010)
In this study, residual stresses introduced via application of shot peening on the raceways of bearing rings and their effect on the fatigue life was investigated experimentally. For improvement of residual compressive stress state, shot peening operation with different parameters was utilized. Residual stress measurements were conducted via X-ray diffraction technique. Optimization of residual stress state during the production of ball bearings is the main target of this study. Process parameters for shot ...
Joint frequency offset and channel estimation
Avan, Muhammet; Candan, Çağatay; Department of Electrical and Electronics Engineering (2008)
In this thesis study, joint frequency offset and channel estimation methods for single-input single-output (SISO) systems are examined. The performance of maximum likelihood estimate of the parameters are studied for different training sequences. Conventionally training sequences are designed solely for the channel estimation purpose. We present a numerical comparison of different training sequences for the joint estimation problem. The performance comparisons are made in terms of mean square estimation err...
High performance short wavelength infrared focal plane arrays
Çırçır, Kübra; Beşikci, Cengiz; Department of Electrical and Electronics Engineering (2017)
Short Wavelength Infrared (SWIR) band is desirable for many applications such as night vision, spectroscopy and hyperspectral imaging. Indium Gallium Arsenide (In0.53Ga0.47As) is a suitable material for SWIR photodetectors. This thesis focuses on the investigation of the pixel characteristics of a 15 µm pitch large format (640x512) focal plane array (FPA) with In0.53Ga0.47As absorber and Al0.52In0.48As p-type cap layers as an alternative to the conventional In0.53Ga0.47As detectors utilizing InP as the p-ca...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
E. GHALICHI and N. G. Gençer, “Theoretical limits to sensitivity and resolution in magneto-acousto-electrical tomography,”
PHYSICS IN MEDICINE AND BIOLOGY
, pp. 8025–8040, 2017, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/46317.