Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Current injection optimization for magnetic resonance-electrical impedance tomography (MREIT)
Date
2007-09-02
Author
Altunel, H.
Eyüboğlu, Behçet Murat
KÖKSAL, ADNAN
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
222
views
0
downloads
Cite This
Determining optimum current injection pattern is of interest in magnetic resonance-electrical impedance tomography (MREIT), since it helps in detecting smaller inhomogeneities within the body when total injected current into the body is limited. Based on this fact, for 2-D cylindrical body with concentric and cylindrical inhomogeneity, current injection optimization problem is analytically formulated, based on distinguishability definition for MREIT. The exterior penalty method is used to solve the optimization problem. In the second step, the same problem is considered for eccentric and cylindrical inhomogeneity and the best current injection pattern is obtained.
Subject Keywords
Current injection
,
Optimization
,
Magnetic resonance
,
Electrical impedance tomography
URI
https://hdl.handle.net/11511/52680
Collections
Department of Electrical and Electronics Engineering, Conference / Seminar
Suggestions
OpenMETU
Core
Distinguishability for Magnetic Resonance-Electric Impedance Tomography (MR-EIT)
Altunel, H.; Eyüboğlu, Behçet Murat; KÖKSAL, ADNAN (2006-09-01)
In magnetic resonance-electrical impedance tomography, magnetic flux density due to current injection is the measured quantity. Different conductivity distributions create different magnetic flux density distributions. Distinguishability for MR-EIT is defined using this fact. The definition is general and valid for 2D as well as 3D structures of any shape. It is not always possible to find an analytic expression for distinguishability. However, when a 2D cylindrical body with concentric inhomogeneity is con...
Equipotential projection based magnetic resonance electrical impedance tomography (mr-eit) for high resolution conductivity imaging
Özdemir, Mahir Sinan; Eyüboğlu, Behçet Murat; Department of Electrical and Electronics Engineering (2003)
In this study, a direct reconstruction algorithm for Magnetic Resonance Electrical Impedance Tomography (MR-EIT) is proposed and experimentally implemented for high resolution true conductivity imaging. In MR-EIT, elec trical impedance tomography (EIT) and magnetic resonance imaging (MRI) are combined together. Current density measurements are obtained making use of Magnetic Resonance Current Density Imaging (MR-CDI) techniques and peripheral potential measurements are determined using conventional EIT tech...
Magnetic Resonance - Electrical Impedance Tomography (MR-EIT) Research at METU
Eyüboğlu, Behçet Murat (2006-09-01)
Following development of magnetic resonance current density imaging (MRCDI), magnetic resonance - electrical impedance tomography (MR-EIT) has emerged as a promising approach to produce high resolution conductivity images. Electric current applied to a conductor results in a potential field and a magnetic flux density distribution. Using a magnetic resonance imaging (MRI) system, the magnetic flux density distribution can be reconstructed as in MRCDI. The flux density is related to the current density distr...
Regional Image Reconstruction with Optimum Currents for MREIT - Evaluation on Shepp-Logan Conductivity Phantom
Eyüboğlu, Behçet Murat; Altunel, Haluk (2008-11-27)
In this study, an image reconstruction algorithm for magnetic resonance electrical impedance tomography (MREIT) is proposed to achieve maximum benefit of optimum current injection patterns. By doing so, considerable reduction in probing current amplitude could be possible. In the proposed algorithm, field of view (FOV) is divided into a number of segments. Image of each segment is reconstructed separately, based on measurements obtained using the best (optimum) current patterns, which maximize distinguishab...
Induced current magnetic resonance electrical impedance tomography (ICMREIT) with low frequency switching of gradient fields
Eroğlu, Hasan Hüseyin; Eyüboğlu, Behçet Murat; Department of Electrical and Electronics Engineering (2017)
In this thesis, it is aimed to investigate induced current magnetic resonance electrical impedance tomography (ICMREIT) starting from modeling and analysis to experimental validation. Forward and inverse problems of ICMREIT are formulated. A magnetic resonance imaging (MRI) pulse sequence is proposed for the realization of ICMREIT using the slice selection (z) gradient coil of MRI scanners. Considering the proposed MRI pulse sequence, relationship between the low frequency (LF) MR phase and the secondary ma...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
H. Altunel, B. M. Eyüboğlu, and A. KÖKSAL, “Current injection optimization for magnetic resonance-electrical impedance tomography (MREIT),” 2007, vol. 17, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/52680.