Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Range and Angle Measurement in a Linear Pulsed Frequency Diverse Array Radar
Date
2017-05-12
Author
Cetiner, Ramazan
Demir, Şimşek
Hizal, Altunkan
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
193
views
0
downloads
Cite This
The range-angle coupling in Frequency Diverse Array (FDA) radar is uniquely solved. The array operates as a linear pulsed FDA in the transmission (TX) mode while it operates as a pulsed phased array (PA) in the receiving (RX) mode. The duration of FDA TX pulse is chosen as minimum. A novel radar concept is proposed. It is shown that FDA waveform can be further compressed by matched filtering (MF).
Subject Keywords
Frequency diverse array
,
Phased array radar
URI
https://hdl.handle.net/11511/53922
Collections
Department of Electrical and Electronics Engineering, Conference / Seminar
Suggestions
OpenMETU
Core
Prospects of FMCW-based frequency diverse array radar
Cetiner, Ramazan; Cetintepe, Cagri; Demir, Şimşek; Hizal, Altunkan (2019-11-01)
The linear frequency modulated (LFM) frequency modulated continuous wave (FMCW)-based frequency diverse array (FDA) radar concept is investigated in detail. The radar operates as a linear pulsed FMCW/FDA in the transmission (TX) mode while it operates as a pulsed FMCW/phased array (PA) in the receiving mode. The issues such as low signal-to-noise ratio (SNR) of FDA, the time-angle scanning and time-range ambiguities are studied. It is shown that the local instantaneous frequency bandwidth is much smaller th...
A Study on the Performance of a Complementary Auxiliary Antenna Pattern for Maisel Sidelobe Blanker
DINLER, Dogancan; Candan, Çağatay; KOC, Sencer (2018-04-27)
The problem of coupling between probability of target blanking (P-TB) and probability of blanking (P-B) in Maisel sidelobe blanker (SLB) is addressed and a complementary auxiliary antenna pattern is proposed for phased array radar systems. The numerical results indicate that the complementary pattern provides an improvement on P-TB and P-B especially for the cases where antennas have poor mainlobe-to-sidelobe ratio.
Partly-filled nonuniform linear arrays for DOA estimation in multipath signals
Tuncer, Temel Engin; Friedlander, Benjamin (2007-04-20)
Partly-filled nonuniform linear arrays (PFNLA) are presented and DOA estimation problem for multipath signals is investigated. A new approach is proposed for DOA estimation in nonuniform linear arrays (NLA) based on array interpolation. A Wiener formulation is used to improve the condition number of the mapping matrix as well as the performance for noisy observations. An initial DOA estimate is obtained by using the uniform part of the PFNLA. This initial estimate is used in array interpolation and a new co...
Direction finding with a uniform circular array via single snapshot processing
Koc, AT; Tanik, Y (1997-01-01)
In this work a new algorithm for multiple emitter direction finding by using a uniform circular array is proposed. The algorithm is based on single snapshot processing, and therefore, it has no restriction on the coherency of the sources. The problem formulation is based on the transformation of the snapshot. The transformed sequence is formed by taking the discrete Fourier transform of the snapshot and weighting it suitably. It contains the so-called distortion terms, which are taken into account by using ...
Examination of Target RCS Characteristics in FDA Radars
Cetintepe, Cagri; Demir, Şimşek (2014-07-11)
This paper reports on the preliminary analysis of frequency diverse array (FDA) radars for simple target geometries. The radar system employs an FDA and a isotropic element as the transmitter and receiver antennas, respectively, and illuminates a target consisting of an arbitrary arrangement of ideal point scatterers. After establishing a signal model for the voltage waveform received by this radar system, the study then considers particular target arrangements and compares the average received power to tha...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
R. Cetiner, Ş. Demir, and A. Hizal, “Range and Angle Measurement in a Linear Pulsed Frequency Diverse Array Radar,” 2017, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/53922.