Comparative Power Loss Analysis of DCM Flyback Transformer Based on FEA, Numeric Simulation, Calculation and Measurements

2019-01-01
Onay, Halil
Suel, Volkan
Ozgen, Tayfun
Hava, Ahmet Masum
The flyback transformer is a crucial part of the flyback converter, which has the highest portion of total power losses for most applications. Accurately prediction of the power losses due to flyback transformer early in the design stage provides an advantage about revealing reliable prototypes. In this paper, several loss prediction methods are applied for a 40W universal input and single output DCM flyback transformer as; analytical calculations via well-known Steinmetz and Dowell's formulas, a simulation including numerical solutions, and a finite element analysis (FEA) based investigation. It is shown that the comprehensiveness of the methods accounting for hysteresis losses, eddy current losses, DC bias, and fringing effect based losses determine the accuracy of the results. In the paper, it is shown that the more the comprehensiveness, the closer the results to the values of electrical and thermal measurements. The power loss results obtained from theory and measurements with five different methods are compared and discussed in the detail.

Suggestions

Active clamped ZVS forward converter with soft-switched synchronous rectifier for maximum efficiency operation
Acik, A; Cadirci, I (1998-05-22)
An active-clamped, zero-voltage switched forward converter equipped with a soft-switched synchronous rectifier is designed and implemented for some low output voltage applications where maximized efficiency is of utmost importance. The converter efficiency is maximized due to soft-switching of the main, active clamp and the synchronous rectifier MOSFET switches. Experimental results are presented for a converter with a de input voltage of 48V, an output voltage of 5V and a de electronic load up to 10A. The ...
Optimizing transient and filtering performance of a C-type 2nd harmonic power filter by the use of solid-state switches
Gerçek, Cem Özgür; Ertaş, Arif; Department of Electrical and Electronics Engineering (2007)
In this research work, the performance of a C-type, 2nd harmonic power filter is optimized by the use of a thyristor switched damping resistor. In the design of conventional C-type, 2nd harmonic filters; the resistance of permanently connected damping resistor is to be optimized for minimization of voltage stresses on filter elements arising from switchings in transient state and for maximization of filtering effectiveness in the steady-state. Transformer inrush current during energization of power transfor...
Improvement of the electric field distribution in the medium voltage gas insulated inductive voltage transformers
Var, Melih; Keysan, Ozan; Department of Electrical and Electronics Engineering (2017)
IVoltage transformers are commonly used in medium voltage systems for both protection and measurement purposes. These transformers are designed to satisfy the mandatory IEC requirements at the lowest possible cost. The average life expectancy of such transformer is about 20 years, reliability and robustness are of the utmost importance. The main cause of failure during rated operation is the deterioration of the solid insulation by partial discharges. Partial discharges, unless there is a manufacturing erro...
Investigation of multilevel inverters for d-statcom applications
Deniz, Mustafa; Ermiş, Muammer; Department of Electrical and Electronics Engineering (2009)
The most important advantages of Multilevel Inverters are the absence of a coupling transformer for medium voltage applications and low harmonic current content. In this way, relocatable and economical STATCOM systems can be realized. Complex control algorithms and the isolation problems of measurement devices and power supplies are the main challenging parts of this type of application. In this study, the design, realization, and the performance of a Voltage Source Type Cascaded Multilevel Converter Based ...
Operating principles and practical design aspects of all SiC DC/AC/DC converter for MPPT in grid-connected PV supplies
ÖZTÜRK, SERKAN; Popos, Polat; Utalay, Volkan; Koc, Atila; Ermiş, Muammer; ÇADIRCI, IŞIK (2018-12-01)
A 20 kW, 20 kHz high frequency (HF) link maximum power point tracking (MPPT) converter for a grid-connected PV supply, based on all silicon carbide (SiC) power semiconductors, is presented. In the developed converter, SiC power MOSFETs are used in the low-voltage PV panel side and SiC Schottky diodes on the high-voltage DC output, in order to maximize the power conversion efficiency and the power density. Operating principles of the resulting dual H-bridge MPPT converter and the practical aspects of the con...
Citation Formats
H. Onay, V. Suel, T. Ozgen, and A. M. Hava, “Comparative Power Loss Analysis of DCM Flyback Transformer Based on FEA, Numeric Simulation, Calculation and Measurements,” 2019, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/57209.