Protection of high-voltage installations againist overvoltages using protective devices.

1974
Ünver, Uğur

Suggestions

Protection of MV and HV shunt capacitor banks.
Türkyılmaz, Ali Osman; Department of Electrical and Electronics Engineering (1987)
Protection of transmission lines against switching over voltages
Elmas, Erinç Evren; Ertaş, Arif; Department of Electrical and Electronics Engineering (2004)
Any switching action or lightning stroke on a transmission system causes excessive of voltage, which are propagated through the equipment. The withstand capability of the electrical equipment to these overvoltages is dependent on the rate of rise, peak value and the duration of these overvoltages and are especially critical to information technology (IT) equipment. Whenever there is a probability of these overvoltages appearing across the electrical equipment, they should be limited to a safe value by the a...
Protective Measures against Waterhammer in Run of River Hydropower Plants
Çalamak, Melih; Bozkuş, Zafer (2012-10-01)
Waterhammer is an unsteady hydraulic problem which is commonly found in the penstocks of hydropower plants, water distribution networks and pipeline systems. Due to either a malfunction of the system or inadequate operation conditions, pipeline may collapse or burst. In this paper protective measures against waterhammer problems in the penstocks of small hydropower plants are investigated. In the study, a computer program employing method of characteristics is used to solve nonlinear partial differential eq...
Protective measures against waterhammer in run-of-river hydropower plants
Çalamak, Melih; Bozkuş, Zafer (2012-12-01)
Waterhammer is an unsteady hydraulic problem which is commonly found in the penstocks of hydropower plants, water distribution networks and pipeline systems. Due to either a malfunction of the system or inadequate operation conditions, pipeline may collapse or burst. In this paper protective measures against waterhammer problems in the penstocks of small hydropower plants are investigated. In the study, a computer program employing method of characteristics is used to solve nonlinear partial differential eq...
Protective measures against waterhammer in run-of-river hydropower plants
Çalamak, Melih; Bozkuş, Zafer (2012-12-01)
Waterhammer is an unsteady hydraulic problem which is commonly found in the penstocks of hydropower plants, water distribution networks and pipeline systems. Due to either a malfunction of the system or inadequate operation conditions, pipeline may collapse or burst. In this paper protective measures against waterhammer problems in the penstocks of small hydropower plants are investigated. In the study, a computer program employing method of characteristics is used to solve nonlinear partial differential eq...
Citation Formats
U. Ünver, “Protection of high-voltage installations againist overvoltages using protective devices.,” Middle East Technical University, 1974.