Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Terminal voltage regulation of a self excited induction generator by means of a static exciter.
Date
1982
Author
Dağdelen, Mustafa
Metadata
Show full item record
Item Usage Stats
159
views
0
downloads
Cite This
URI
https://hdl.handle.net/11511/6608
Collections
Graduate School of Natural and Applied Sciences, Thesis
Suggestions
OpenMETU
Core
Transient performance of cascaded protective current transformers.
Ceyhan, Mehmet Erdal; Department of Electrical Engineering (1972)
Transient performance of transmission lines under energisation conditions.
Gökçe, Ferit H; Department of Electrical Engineering (1973)
Closed loop speed control of a squirrel cage induction motor by a variable frequency supply.
Nalçaci, A Erbil; Department of Electrical Engineering (1981)
Series active filter design, control, and implementation with a novel load voltage harmonic extraction method
Şentürk, Osman Selçuk; Hava, Ahmet Masum; Department of Electrical and Electronics Engineering (2007)
Series Active Filters (SAF) are designed for harmonic isolation and load voltage regulation of single-phase and three-phase voltage harmonic source type nonlinear loads. The novel Absolute Value Method (AVM) for load voltage harmonic extraction is proposed and applied in the control algorithm of SAF. The SAF compensated systems are represented by simplified linear models such that SAF controller gains can be easily determined. Harmonic isolation and load voltage regulation performances of 2.5 kW single-phas...
Broadband Impedance Transformation by Defected Dielectric on Microstrip Lines
Kaya, Tevfik; Nesimoglu, Tayfun (2018-11-02)
In this work, a different approach to achieve a desired characteristic impedance value on microstrips is presented. In standard microwave circuits using microstrip lines, the dielectric thickness is same and uniform across the whole circuit. In this paper, it is proposed to modify the dielectric thickness to achieve a certain design goal by creating variations in the characteristic impedance of the microstrip transmission line without changing the width of the line. The proposed approach is applied to a mul...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
M. Dağdelen, “Terminal voltage regulation of a self excited induction generator by means of a static exciter.,” Middle East Technical University, 1982.