A two-dimensional laterally averaged hydrodynamic and water quality model (CE-QUAL-WS) is used to simulate the water quality behavior in the proposed Isikli Reservoir of the Ankara Water Supply System to determine appropriate strategies for the management of water quality.

Suggestions

Optimal operation of water distribution pumps considering water quality
Altan Sakarya, Ayşe Burcu (American Society of Civil Engineers (ASCE), 2000-07-01)
A new methodology has been developed for determining the optimal operation of water distribution system pumps with water quality considerations. The methodology is based upon describing the operation as a discrete time optimal scheduling problem that can be used to determine the optimal operation schedules of the pumps in distribution systems. The solution methodology is based upon a mathematical programming approach resulting in a large-scale nonlinear programming problem that cannot be solved using existi...
New methodologies for optimal operation of water distribution systems for water quality purposes
Altan Sakarya, Ayşe Burcu; Mays, LW (1998-01-01)
Two new methodologies have been developed for determining the optimal operation of water distribution systems for water quality purposes. These methodologies are based upon describing the operation as a discrete time optimal control problem that can be used to determine the optimal operation schedules of the pumps in distribution systems. One solution methodology is based upon a mathematical programming approach and the second methodology is based upon a simulated annealing approach. These two methodologies...
Evaluation of eutrophication control strategies for the Keban Dam reservoir
Soyupak, S; Mukhallalati, L; Yemisen, D; Bayar, A; Yurteri, C (1997-04-15)
The reservoir of the Keban Dam in eastern Anatolia is a very deep and large water body subject to significant seasonal water level fluctuations within a given hydrological year. At the present time, different sections of the reservoir have different trophic status and the upper portion of the reservoir, in particular, is eutrophic. In this regard, there is a need for the assessment of alternative strategies to be implemented for phosphorus and thus eutrophication control in this segment of the reservoir. In...
Spatial data analysis for monitoring and prediction of selected water quality parameters in reservoirs: Porsuk Dam reservoir case
Yenilmez, Firdes; Aksoy, Ayşegül; Düzgün, H. Şebnem; Department of Environmental Engineering (2014)
In the design of a water quality monitoring network, selection of water quality sampling locations is crucial to adequately represent the water quality of the water body when high costs of analyses and field work are taken into account. In this study, a new approach was proposed to identify the representative water quality sampling locations in reservoirs and lakes using geostatistical tools for estimation of spatial distribution of selected water quality parameters. To do so, kernel density estimation (KDE...
Rehabilitation of water supply systems
Toğrul, Nevzat; Merzi, Nuri; Department of Civil Engineering (2015)
Management of water supply systems by an economic and efficient way is a significant issue for water authorities. Selection and operation of water supply elements appropriately to satisfy water need affects the energy consumption of the system. This study aims to constitute a long term rehabilitation plan for water supply elements (only storage tanks, pumps and transmission line pipes are in the scope of the study). A case study has been performed on N8.3 pressure zone of Ankara water distribution network. ...
Citation Formats
O. Gunduz, S. Soyupak, and C. Yurteri, “Development of water quality management strategies for the proposed Isikli reservoir,” 1998, vol. 37, p. 369, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/66793.