Comparison of transient two-phase flow instabilities in a four parallel channel upflow system with and without cross-connections.

1975
Özboya, Nail

Suggestions

Comparison of sustained boiling flow instabilities in a four parallel channel system with and without cross-connections.
Yamalı, Cemil; Department of Mechanical Engineering (1976)
Comparison of Fully Coupled and DecoupledModeling Results of Graphite Ablation In Hypersonic Flows
Onay, Oğuz; Eyi, Sinan (2019-09-20)
A thermochemical ablation modeling tool is developed for graphite material in air for reactive hypersonic flows. Multi-species and axisymmetric Navier-Stokes equations are solved for the flow field analysis. Arrhennius type of relations are utilized for finite rate reactions and chemical equilibrium is assumed on the eroding wall of graphite material. Total of thirteen species are included in the analysis in which eight of them are the products of the graphitic material ablation. Flow field, surface thermoc...
Comparison of low and high Pd loadings on CNTs via supercritical fluid deposition as hydrogen storage materials
Erünal, Ebru; Ulusal, Fatma; Odabaşı, Selda; Aslan, Mustafa Yasin; Güzel, Bilgehan; Üner, Deniz (2018-04-28)
Comparison of damage mechanisms in curved composite laminates under static and fatigue loading
Tasdemir, B.; Çöker, Demirkan (Elsevier BV, 2019-04-01)
In this paper, damage progression in curved CFRP composite laminates are experimentally investigated for static and fatigue loadings. Two different cross-ply laminate thicknesses are examined with grouped plies to elucidate the failure mechanisms. A test fixture is designed to apply moment/axial combined loading to curved specimens and DIC method is used to obtain the strain distribution in the curved region until failure. Our major finding is that under fatigue loading, the failure location and mechanism a...
Comparison of multi-phase interleaved boost converters with various coupled inductor topologies
Gökmen, Raşit; Bostancı, Emine; Department of Electrical and Electronics Engineering (2022-2)
Multi-phase interleaved boost converters are widely used in high power applications thanks to their high efficiency, high power density, increased output power capability and low input current ripple features. However, increasing the phase number results in an increase in the overall volume of the converter. In order to reduce the volume of the converter, inductors in multi-phase interleaved boost converters can be coupled. For a two-phase interleaved boost converter, loosely-coupled inductor (LCI), close-c...
Citation Formats
N. Özboya, “Comparison of transient two-phase flow instabilities in a four parallel channel upflow system with and without cross-connections.,” Middle East Technical University, 1975.