Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
High-throughput solid phase microextraction as a convenient sample preparation approach for analysis of prohibited substances in body fluids
Date
2014-09-30
Author
Reyes-garcés, Nathaly
Boyacı, Ezel
Gorynski, K.
Rodríguez-lafuente, Angel
Bojko, Barbara
Pawliszyn, Janusz
Metadata
Show full item record
Item Usage Stats
99
views
0
downloads
Cite This
URI
https://hdl.handle.net/11511/83641
Collections
Unverified, Article
Suggestions
OpenMETU
Core
High-throughput solid phase microextraction (SPME)-LC-MS as a convenient method for the simultaneous determination of multiple prohibited substances in urine and plasma
Reyes-garcés, Nathaly; Boyacı, Ezel; Gorynski, K.; Rodríguez-lafuente, Angel; Bojko, Barbara; Pawliszyn, Janusz (2014-09-18)
High-Resolution Solar Imaging With Photon Sieves
Öktem, Sevinç Figen; Davila, Joseph M (2014-12-15)
A photon sieve is a modification of a Fresnel zone plate in which open zones are replaced by a large number of circular holes. This lightweight optical device offers a superior image forming capability compared with the Fresnel zone plate, and is specially suited to observations at UV and x-ray wavelengths where refractive lenses are not available due to strong absorption of materials, and reflective mirrors are difficult to manufacture to achieve near diffraction-limited resolution. At these shorter wavele...
High-frequency CMUT arrays for high-resolution medical imaging
Oralkan, O; Hansen, ST; Bayram, Barış; Yaralioglu, GG; Ergun, AS; Khuri-Yakob, BT (2004-01-01)
This paper describes high-frequency I-D CMUT arrays designed and fabricated for use in electronically scanned high-resolution ultrasonic imaging systems. Two different designs of 64-element linear CMUT arrays are presented in this paper. A single element in each array is connected to a single-channel custom front-end integrated circuit for pulse-echo operation. The first design has a resonant frequency of 43 MHz in air, and operates at 30 MHz in immersion. The second design exhibits a resonant frequency of ...
High-performance SOI-MEMS gyroscope with decoupled oscillation modes
Alper, Se; Azgın, Kıvanç; Akın, Tayfun (2006-01-26)
This paper presents a new, high-performance SOI-MEMS gyroscope with decoupled oscillation modes. The gyroscope structure allows to achieve matched-resonance-frequencies, large drive-mode oscillation amplitude, high sense-mode quality factor, and low mechanical crosstalk, demonstrating a measured noise-equivalent rate of 90 (deg/hr)/Hz(1/2) even at atmospheric pressure. The angular rate sensitivity of the gyroscope is 100 mu V/(deg/sec) at atmospheric pressure. This value improves to 2.4mV/(deg/sec) at vacuu...
High Haze Nano Textured Aluminum doped Zinc Oxide withPlasmonic Silver Nanoparticles for Enhanced Optical Absorption and Photocurrent of a Si H thin film
Nasser, Hisham; Özkol, Engin; Bek, Alpan; Turan, Raşit (null; 2015-01-15)
We report on fabrication of plasmonic interfaces consisting of Ag nanoparticles on flat and textured Al:ZnO for use at the front surface of thin film solar cells to enhance light trapping and photo-conversion efficiencies. We show that outstandingly high transmittance haze is achieved from single step HCl surface textured Al:ZnO and demonstrate Ag dewetting on textured and flat Al:ZnO surfaces upon annealing at moderate temperatures. Optical response of these plasmonic interfaces clearly display plasmonic r...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
N. Reyes-garcés, E. Boyacı, K. Gorynski, A. Rodríguez-lafuente, B. Bojko, and J. Pawliszyn, “High-throughput solid phase microextraction as a convenient sample preparation approach for analysis of prohibited substances in body fluids,” 2014, Accessed: 00, 2021. [Online]. Available: https://hdl.handle.net/11511/83641.