Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Implementation of a prototype thyristorized reactive power compensator
Download
003591.pdf
Date
1988
Author
Pişkin, M Sadık
Metadata
Show full item record
Item Usage Stats
66
views
0
downloads
Cite This
URI
https://hdl.handle.net/11511/8442
Collections
Graduate School of Natural and Applied Sciences, Thesis
Suggestions
OpenMETU
Core
Implementation of a multiband excitation speech coder
İnevi, Mete; Demirekler, Mübeccel; Department of Electrical and Electronics Engineering (1999)
Implementation of a data acquisition system for contactless conductivity imaging
Ulker, B; Gençer, Nevzat Güneri (2002-09-01)
A data acquisition system is realized for conductivity imaging via contactless measurements. It is observed that field profiles are good representatives of the conductive objects scanned by the measurement system. Three different data sets are taken with different scanning resolutions. Note that although the scanning resolution is decreased 25 times, it is still possible to observe the conductive object. The data acquisition time is due to the data acquisition time limit of the lock-in amplifier. As might b...
Implementation of a data acquisition system for contactless conductivity imaging
ULKER, B; Gençer, Nevzat Güneri (2001-10-28)
A data acquisition system is realized to image electrical conductivity of biological tissues via contactless measurements. This system uses magnetic excitation to induce currents inside the body and measures the magnetic fields of the induced currents. A magnetically coupled differential coil system is scanned on the conductive object by a computer controlled scanning system. A data acquisition system is constructed using a PC controlled lock-in amplifier. 1.64V secondary voltage difference can be measured ...
Implementation of a digital signal synthesizer with high spurious free dynamic range
Kılıç, Argun; Yılmaz, Ali Özgür; Department of Electrical and Electronics Engineering (2006)
Today’s analog modulators and upconverters are inadequate to synthesize and modulate signals with high ‘Spurious Free Dynamic Range’ (SFDR). Thus, the main objective of this thesis is to design and implement a ‘Digital Signal Synthesizer’ (DSS) that is capable of synthesizing signals between 50-100 MHz with 60dB SFDR and to modulate them variable symbol rates and modulation techniques with very high phase/frequency resolution and switching speed while keeping the amplitude modulation occurring during a modu...
Implementation of Dirlik s damage model for the vibration fatigue analysis
Demirel, İsmail Gürzap; Kayran, Altan (2019-01-01)
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
M. S. Pişkin, “Implementation of a prototype thyristorized reactive power compensator,” Middle East Technical University, 1988.