Emission characteristics for gaseous- and size-segregated particulate PAHs in coal combustion flue gas from circulating fluidized bed (CFB) boiler

2018-07-01
Wang, Ruwei
Liu, Guijian
Sun, Ruoyu
Yousaf, Balal
Wang, Jizhong
Liu, Rongqiong
Zhang, Hong
The partitioning behavior of polycyclic aromatic hydrocarbons (PAHs) between gaseous and particulate phases from coal-fired power plants (CFPPs) is critically important to predict PAH removal by dust control devices. In this study, 16 US-EPA priority PAHs in gaseous and size-segregated particulate phases at the inlet and outlet of the fabric filter unit (FFs) of a circulating fluidized bed (CFB) boiler were analyzed. The partitioning mechanisms of PAHs between gaseous and particulate phases and in particles of different size classes were investigated. We found that the removal efficiencies of PAHs are 45.59% and 70.67-89.06% for gaseous and particulate phases, respectively. The gaseous phase mainly contains low molecular weight (LMW) PAHs (2- and 3-ring PAHs), which is quite different from the particulate phase that mainly contains medium and high molecular weight (MMW and HMW) PAHs (4- to 6-ring PAHs). The fractions of LMW PAHs show a declining trend with the decrease of particle size. The gas-particle partitioning of PAHs is primarily controlled by organic carbon absorption, in addition, it has a clear dependence on the particle sizes. Plot of log (TPAH/PM) against logD(p) shows that all slope values were below 1, suggesting that PAHs were mainly adsorbed to particulates. The adsorption effect of PAHs in size-segregated PMs for HMW PAHs is more evident than LMW PAHs. The particle size distributions (PSDs) of individual PAHs show that most of PAHs exhibit bi-model structures, with one mode peaking in the accumulation size range (2.1-1.1 mu m) and another mode peaking in coarse size range (5.8-4.7 mu rn). The intensities of these two peaks vary in function of ring number of PAHs, which is likely attributed to Kelvin effect that the less volatile HMW PAH species preferentially condense onto the finer particulates. The emission factor of PAHs was calculated as 3.53 mg/kg of coal burned, with overall mean EFpAH of 0.55 and 2.98 mg/kg for gaseous and particulate phase, respectively. Moreover, the average emission amount of PAHs for the investigated CFPP was 1016.6 g/day and 371073.6 g/y, respectively. (C) 2018 Elsevier Ltd. All rights reserved.
ENVIRONMENTAL POLLUTION

Suggestions

Emission characterization and delta C-13 values of parent PAHs and nitro-PAHs in size-segregated particulate matters from coal-fired power plants
Wang, Ruwei; Yousaf, Balal; Sun, Ruoyu; Zhang, Hong; Zhang, Jiamei; Liu, Guijian (2016-11-01)
The objective of this study was to characterize parent polycyclic aromatic hydrocarbons (pPAHs) and their nitrated derivatives (NPAHs) in coarse (PM2.5-10), intermediate (PW1-2.5) and fine (PM1) particulate matters emitted from coal-fired power plants (CFPPs) in Huainan, China. The diagnostic ratios and the stable carbon isotopic approaches to characterize individual PAHs were applied in order to develop robust tools for tracing the origins of PAHs in different size-segregated particular matters (PMs) emitt...
CATALYTIC CHARACTERISTICS OF MASSIVE AND LOADED SULFONIC RESINS IN THE SYNTHESIS OF ETHYL tert-BUTYL ETHER AT ATMOSPHERIC AND INCREASED PRESSURE
Vlasenko, N. V.; Kochkin, Yu. N.; Strizhak, P. E.; Doğu, Timur; DOĞU, GÜLŞEN; OKTAR, NURAY; Degirmenci, L. (Springer Science and Business Media LLC, 2010-11-01)
The catalytic characteristics of massive and loaded sulfonic resins in the synthesis of ethyl tert-butyl ether at atmospheric and increased pressures have been compared. It has been established that massive sulfonic resins are more active than loaded resins at atmospheric pressure. At higher pressures, on the other hand, the activity and selectivity of catalysts are greater the lower the content of polymer as a result of the increased effectiveness of the acid centers.
Axial gas mixing in conical spouted beds with high density particles
Güler, Neslin; KÖKSAL, MURAT; Külah, Görkem (2023-10-01)
Conical spouted beds operating with high-density particles (ρp > 2500 kg/m3) have recently gained attention because of their potential use as nuclear fuel coaters for next-generation nuclear reactors. In the literature, the number of axial gas mixing studies in conical and conical-cylindrical spouted beds is very limited and all axial mixing studies were carried out with relatively light particles (ρp ≤ 2500 kg/m3). Therefore, the objective of this study was to generate experimental data that can be used to...
Emissions of NOx and SO2 from Coals of Various Ranks, Bagasse, and Coal-Bagasse Blends Burning in O-2/N-2 and O-2/CO2 Environments
Kazanç Özerinç, Feyza; Crnkovic, Paula Manoel; Levendis, Yiannis A. (2011-07-01)
Oxy-coal combustion is a viable technology, for new and existing coal-fired power plants, as it facilitates carbon capture and, thereby, can mitigate climate change. Pulverized coals of various ranks, biomass, and their blends were burned to assess the evolution of combustion effluent gases, such as NOx, SO2, and CO, under a variety of background gas compositions. The fuels were burned in an electrically heated laboratory drop-tube furnace in O-2/N-2 and O-2/CO2 environments with oxygen mole fractions of 20...
Methane to higher hydrocarbons via halogenation
Degirmenci, V; Üner, Deniz; Yılmaz, Ayşen (Elsevier BV, 2005-10-15)
Activation of methane with a halogen followed by the metathesis of methyl halide is a novel route from methane to higher hydrocarbons or oxygenates. Thermodynamic analysis revealed that bromine is the most suitable halogen for this goal. Analysis of the published data on the reaction kinetics in a CSTR enabled us to judge on the effects of temperature, reactor residence time and the feed concentrations of bromine and methane to the conversion of methane and the selectivity towards mono or dibromomethane. Th...
Citation Formats
R. Wang et al., “Emission characteristics for gaseous- and size-segregated particulate PAHs in coal combustion flue gas from circulating fluidized bed (CFB) boiler,” ENVIRONMENTAL POLLUTION, pp. 581–589, 2018, Accessed: 00, 2021. [Online]. Available: https://hdl.handle.net/11511/89965.