Variable temperature Scanning Hall Probe Microscopy (SHPM) using quartz crystal AFM feedback

2006-12-01
Dede, M.
Urkmen, K.
Oral, Ahmet
Farrer, I.
Ritchie, D.A.
Scanning Hall Probe Microscopy (SHPM)[1] is a quantitative and non-invasive technique for imaging localized surface magnetic field fluctuations such as ferromagnetic domains with high spatial and magnetic field resolution of ∼50nm [2] and 7mG/√Hz at room temperature. In the SHPM technique, Scanning Tunneling Microscope (STM) [1] or Atomic Force Microscope (AFM)[3] feedback is used to keep the Hall sensor in close proximity of the sample. However, STM tracking SHPM requires conductive samples; therefore the insulating substrates have to be coated with a thin layer of gold. This constraint can be eliminated with the AFM feedback using sophisticated Hall probes that are integrated with AFM cantilevers. However it is very difficult to micro fabricate these sensors. In this work, we have eliminated the difficulty in the cantilever-Hall probe integration process, just by gluing a Hall Probe chip to a quartz crystal tuning fork force sensor. The resultant SHPM can operate in variable temperature environment, 77-300K. The 800nm size Hall sensors are microfabricated in a class 100 clean room facility. The Hall sensor chip is simply glued at the end of a 32,768 Hz Quartz crystal, which is used as force sensor as shown in Fig. 1. An LT-SHPM system is used to scan the samples as shown in Fig. 2. The sensor assembly is dithered at the resonance frequency using a digital Phase Locked Loop circuit and frequency shifts are used for AFM tracking. SHPM electronics is modified to detect AFM topography and the phase, along with the magnetic field image. Magnetic domains and topography of the Iron Garnet thin film crystal, NdFeB demagnetised magnet and hard disk samples are imaged at 300K as shown in Fig 3 with the Quartz Crystal AFM feedback. The system is designed to operate down to 1K, but it could only be tested down to 77K for the moment, as shown in Fig. 4. In conclusion, the performance is found to be comparable with the SHPM using STM feedback under variable temperature operation. Quartz Crystal AFM feedback offers a very simple sensor fabrication and operation in SHPM. This method eliminates the necessity of conducting samples for SHPM.
INTERMAG 2006 - IEEE International Magnetics Conference

Suggestions

Scanning Hall Probe Microscopy (SHPM) using quartz crystal AFM feedback
Dede, M.; Uerkmen, K.; Girisen, Oe.; Atabak, M.; Oral, Ahmet; Farrer, I.; Ritchie, D. (American Scientific Publishers, 2008-02-01)
Scanning Hall Probe Microscopy (SHPM) is a quantitative and non-invasive technique for imaging localized surface magnetic field fluctuations such as ferromagnetic domains with high spatial and magnetic field resolution of similar to 50 nm and 7 mG/Hz(1/2) at room temperature. In the SHPM technique, scanning tunneling microscope (STM) or atomic force microscope (AFM) feedback is used to keep the Hall sensor in close proximity of the sample surface. However, STM tracking SHPM requires conductive samples; ther...
RT-SHPM imaging of permalloy microstructures and garnet films using new high performance InSb sensors
Kaval, M.; Oral, Ahmet; Dede, M.; Sandhu, A. (2002-01-01)
Scanning Hall probe microscopy (SHPM) is a quantitative and noninvasive technique to image magnetic samples with high spatial and magnetic field resolution: ∼120 nm & 6×10-6T/√(Hz) at room temperature. A sub-micron Hall probe is scanned over the sample surface to measure the surface magnetic fields using conventional scanning tunneling microscopy-positioning techniques. We have developed new low noise, high performance InSb Hall sensors for room temperature scanning Hall probe microscopy (RT-SHPM), which ha...
Electrical impedance tomography using the magnetic field generated by injected currents
Birgul, O; Ider, YZ (1996-11-03)
In 2D EIT imaging, the internal distribution of the injected currents generate a magnetic field in the imaging region which can be measured by magnetic resonance imaging techniques. This magnetic field is perpendicular to the imaging region on the imaging region and it can be used in reconstructing the conductivity distribution inside the imaging region. For this purpose, internal current distribution is found using the finite element method. The magnetic fields due to this current is found using Biot-Savar...
3D scanning Hall probe microscopy with 700 nm resolution
DEDE, MUNIR; AKRAM, RİZWAN; Oral, Ahmet (2016-10-31)
In this report, we present a three dimensional (3D) imaging of magnetic field vector (B) over right arrow (x,y,z) emanating from the magnetic material surfaces using a scanning Hall probe microscopy (3D-SHPM) down to a 700 nm spatial resolution. The Hall probe is used to measure B-z(x,y) on the specimen surface at different heights with the step size of Delta z = 250 nm, as we move away from the surface in z direction, until the field decays to zero. These set of images are then used to get partial derivati...
Scanning Hall probe microscopy of superconductors and magnetic materials
Oral, Ahmet; Henini, M (1996-03-01)
We describe results from a scanning Hall probe microscope operating in a broad temperature range, 4-300 K. A submicron Hall probe manufactured in a GaAs/AlGaAs two-dimensional electron gas is scanned over the sample to measure the surface magnetic fields using conventional scanning tunneling microscopy positioning techniques, The magnetic field structure of the sample together with the topography can be obtained simultaneously, The technique is noninvasive with an extremely low self-field of < 10(-2) G and ...
Citation Formats
M. Dede, K. Urkmen, A. Oral, I. Farrer, and D. A. Ritchie, “Variable temperature Scanning Hall Probe Microscopy (SHPM) using quartz crystal AFM feedback,” presented at the INTERMAG 2006 - IEEE International Magnetics Conference, San Diego, CA, Amerika Birleşik Devletleri, 2006, Accessed: 00, 2021. [Online]. Available: https://hdl.handle.net/11511/94521.