Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Factors affecting particle number size distributions at a suburban and a rural site at the Anatolian Plateau
Date
2022-07-01
Author
Uzunpınar, Elif Sena
İmamoğlu, İpek
Rahmani, Amir
Tuncel, Süleyman Gürdal
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
105
views
0
downloads
Cite This
© 2022 Turkish National Committee for Air Pollution Research and ControlIn this work, number size distributions of particles between 0.2 and 34 μm were measured with a laser spectrometer. Temporal and spatial variability in size distributions were investigated. Measurements were carried out at two stations; the Mediterranean coast of Turkey (Marmaris) and central Anatolia (Ankara). PM1, PM2.5, and PM10 mass concentrations were measured. Flow climatology indicated that air masses spent more time in the south of Mediterranean basin in winter and in the North of the basin during summer months. Median PM10 concentrations measured in Marmaris and Ankara stations were 17 and 38 μg m−3, respectively. North African dust transport was not the main PM10 source in the suburban station, but it was significant in the rural station. The median PM2.5 concentration was higher at Ankara due to anthropogenic emissions which was not observed in Marmaris. Median PM1 concentrations were comparable in both stations. 90–95% of the particles were between 0.26 and 0.42 μm size ranges. Coarse particle concentrations were higher at the suburban station, whereas fine particles were higher at the rural station. Concentrations depicted a well-defined seasonal pattern in the rural station, with higher concentrations in summer season. Although concentrations of PM size fractions were also higher in the summer season in Ankara station, seasonal differences were not as well-defined as in the rural station. PM1 and PM2.5 concentrations did not show any difference between weekends and weekdays, but PM10 concentrations, particularly the 2.5 μm < D < 10 μm, were higher on weekdays due to contribution of resuspended road dust.
Subject Keywords
Aerosol
,
Dust
,
Long-range transport
,
Number concentration
,
The mediterranean
URI
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85130512136&origin=inward
https://hdl.handle.net/11511/98018
Journal
Atmospheric Pollution Research
DOI
https://doi.org/10.1016/j.apr.2022.101422
Collections
Department of Environmental Engineering, Article
Suggestions
OpenMETU
Core
Effect of meteorology and transport on particle concentrations and size distribution in Eastern Mediterranean atmosphere
Uzunpınar, Elif Sena; Tuncel, Süleyman Gürdal; İmamoğlu, İpek; Department of Environmental Engineering (2022-3-25)
This study aims to examine the relationship between particle sizes and processes in the atmosphere and the effect of dust transport on particle size distribution. Number (0.2 μm to 32 μm) and mass (PM1, PM2.5, and PM10) concentrations were collected at rural (Mediterranean coast - Marmaris) and suburban (Central Anatolia - Ankara) stations between April 1, 2017, and October 31, 2018. The coarse particles were more dominant in the Ankara while the Marmaris contained relatively smaller-sized particles. The lo...
Effect of particle polydispersity on particle concentration measurement by using laser Doppler anemometry
Ayranci, Isil; Pinguet, Guillaume; Escudie, Dany; Selçuk, Nevin; Vaillon, Rodolphe; Andre, Frederic (2007-08-01)
Measurement of particle concentration by laser Doppler anemometry (LDA) is studied on a vertical air jet seeded by a powder disperser with controlled particle and air flow rates. Particle arrival rate is utilized to retrieve particle number densities from conventional LDA operation. The effect of polydisperse nature of the particles is assessed. Comparisons between measured and estimated particle number densities suggest that only a certain portion of the particle population with a particle size to fringe s...
Dose rate effects in the radiation damage of the plastic scintillators of the CMS hadron endcap calorimeter
Khachatryan, V.; et. al. (IOP Publishing, 2016-10-07)
We present measurements of the reduction of light output by plastic scintillators irradiated in the CMS detector during the 8 TeV run of the Large Hadron Collider and show that they indicate a strong dose rate effect. The damage for a given dose is larger for lower dose rate exposures. The results agree with previous measurements of dose rate effects, but are stronger due to the very low dose rates probed. We show that the scaling with dose rate is consistent with that expected from diffusion effects.
Factors Influencing Imazapyr Herbicide Removal from Wastewater Using Photocatalytic Ozonation
Bougarrani, Salma; El Azzouzi, Laila; Akel, Soukaina; Latrach, Lahbib; Bouzıanı, Asmae; El Azzouzi, Mohammed (2018-01-01)
This study investigates the degradation of imazapyr herbicide from wastewater by photocatalytic ozonation using TiO2 as a semiconductor. Effects of operational parameters on imazapyr removal efficiency including TiO2 dosing, initial herbicide concentration and pH were also studied. Obtained results showed that more than 90% of removal efficiency representing the disappearance of imazapyr was maintained until 7 mu M in the presence of 200 mgL(-1) of UV100-TiO2. Otherwise, the degradation of imazapyr followed...
Overview of the beam emission spectroscopy diagnostic system on the National Spherical Torus Experiment
Smith, D. R.; Feder, H.; Feder, R.; Fonck, R. J.; Labik, G.; McKee, G. R.; Schoenbeck, N.; Stratton, B. C.; Uzun Kaymak, İlker Ümit; Winz, G. (AIP Publishing, 2010-10-01)
A beam emission spectroscopy (BES) system has been installed on the National Spherical Torus Experiment (NSTX) to study ion gyroscale fluctuations. The BES system measures D-alpha emission from a deuterium neutral heating beam. The system includes two optical views centered at r/a approximate to 0.45 and 0.85 and aligned to magnetic field pitch angles at the neutral beam. f/1.5 collection optics produce 2-3 cm spot sizes at the neutral beam. The initial channel layout includes radial arrays, poloidal arrays...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
E. S. Uzunpınar, İ. İmamoğlu, A. Rahmani, and S. G. Tuncel, “Factors affecting particle number size distributions at a suburban and a rural site at the Anatolian Plateau,”
Atmospheric Pollution Research
, vol. 13, no. 7, pp. 0–0, 2022, Accessed: 00, 2022. [Online]. Available: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85130512136&origin=inward.