Removal of baseline wandering from the electrocardiogram

Download
2006
Tanrıverdi, Volkan
ECG measures electrical potentials on the body surface via contact electrodes. Conditions such as movement of the patient, breathing, and interaction between the electrodes and skin cause baseline wandering of the ECG signal. Baseline wandering noise can mask some important features of the ECG signal; hence it is desirable to remove this noise for proper analysis of the ECG signal. This study includes an implementation and evaluation of methods to remove this noise, such as finite impulse response filters, infinite impulse response filters, interpolation filters and adaptive filters. These filters are first applied offline to simulated ECG data. The filter outputs and their frequency spectra are compared to the pure ECG signal and its frequency spectrum using visual inspection and numerical evaluation criteria such as root mean squared error and percentage root relative squared error. The best filters are then selected and applied online to the same simulated data. Finally, these best methods are used to suppress the baseline wandering noise in real ECG recordings using both offline and online filtering. In the offline application, windowing type filters were found to be the most successful filters among the implemented filters. However, a high filter order should be used to produce such good results, which increases the computation time, thus it may not be the best method for online filtering, in which fast computation is essential. Butterworth bidirectional type is preferred for online filtering since it has lower computational complexity, and it produces acceptable results.

Suggestions

Optimum current injection strategy for magnetic resonance electrical impedance tomography
Altunel, Haluk; Eyüboğlu, Behçet Murat; Department of Electrical and Electronics Engineering (2008)
In this thesis, optimum current injection strategy for Magnetic Resonance Electrical Impedance Tomography (MREIT) is studied. Distinguishability measure based on magnetic flux density is defined for MREIT. Limit of distinguishability is analytically derived for an infinitely long cylinder with concentric and eccentric inhomogeneities. When distinguishability limits of MREIT and Electrical Impedance Tomography (EIT) are compared, it is found that MREIT is capable of detecting smaller perturbations than EIT. ...
RF coil system design for MRI applications inhomogeneous main magnetic field
Yılmaz, Ayhan Ozan; Aşkar, Murat; Department of Electrical and Electronics Engineering (2007)
In this study, RF coil geometries are designed for MRI applications using inhomogeneous main magnetic fields. The current density distributions that can produce the desired RF magnetic field characteristics are obtained on predefined cubic, cylindrical and planar surfaces and Tikhonov, CGLS, TSVD and Rutisbauer regularization methods are applied to match the desired and generated magnetic fields. The conductor paths, which can produce the current density distribution calculated for each surface selection an...
Performance evaluation of magnetic flux density based magnetic resonance electrical impedance tomography reconstruction algorithms
Eker, Gökhan; Eyüboğlu, Behçet Murat; Department of Electrical and Electronics Engineering (2009)
Magnetic Resonance Electrical Impedance Tomography (MREIT) reconstructs images of electrical conductivity distribution based on magnetic flux density (B) measurements. Magnetic flux density is generated by an externally applied current on the object and measured by a Magnetic Resonance Imaging (MRI) scanner. With the measured data and peripheral voltage measurements, the conductivity distribution of the object can be reconstructed. There are two types of reconstruction algorithms. First type uses current de...
Design and fabrication of rf mems switches and instrumentation for performance evaluation
Atasoy, Halil İbrahim; Demir, Şimşek; Department of Electrical and Electronics Engineering (2007)
This thesis presents the RF and mechanical design of a metal-to-metal contact RF MEMS switch. Metal-to-metal contact RF MEMS switches are especially preferred in low frequency bands where capacitive switches suffer from isolation due to the limited reactance. Frequency band of operation of the designed switch is from DC to beyond X-band. Measured insertion loss of the structure is less than 0.2 dB, return loss is better than 30 dB, and isolation is better than 20 dB up to 20 GHz. Isolation is greater than 2...
Advanced readout and control electronics for mems gyroscopes
Temiz, Yüksel; Akın, Tayfun; Department of Electrical and Electronics Engineering (2007)
This thesis reports the development of advanced readout and control electronics for MEMS gyroscopes developed at METU. These gyroscope electronics are separated into three main groups: high sensitive interface circuits, drive mode amplitude controlled self oscillation loops, and sense mode phase sensitive amplitude demodulators. The proposed circuits are first implemented with discrete components, and then integrated on CMOS chips. A self oscillation loop enabling constant amplitude drive mode vibrations in...
Citation Formats
V. Tanrıverdi, “Removal of baseline wandering from the electrocardiogram,” M.S. - Master of Science, Middle East Technical University, 2006.