Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
The effect of sun spaces on temperature patterns within buildings: two case studies on the METU campus
Download
index.pdf
Date
2009
Author
Kırmızı, Hacer
Metadata
Show full item record
Item Usage Stats
204
views
158
downloads
Cite This
The aim of this study was to investigate the passive and active parameters affecting energy efficiency of two office buildings with sun spaces, namely the MATPUM Building and the Solar Building on the Middle East Technical University (METU) Campus, Ankara and the effect of sun spaces on temperature patterns within mentioned buildings. Both buildings were oriented in the same direction, namely south. However, the location and the type of the sunspaces differed from each other. The sun space in the MATPUM Building is an atrium which has southerly glazed façade. On the other hand, the sun space in the Solar Building is an enclosed conservatory which has southerly glazed façades and roof. The effect of sun spaces on temperature patterns within case study buildings was determined by collecting internal temperature and humidity data from different locations within the buildings and external temperature and humidity data on certain days of the week from May to August and October and November. Data loggers were used to collect these data. The collected data was then compared for the two buildings and also for the different months. In conclusion, more heat gain resulting in temperature increase inside the buildings was obtained in conservatories when compared to the atria which have glazed façade instead of glazed roof. This was also proved by the analysis of variance method which was used for the comparison of temperature data of two buildings.
Subject Keywords
Building science.
URI
http://etd.lib.metu.edu.tr/upload/2/12611427/index.pdf
https://hdl.handle.net/11511/19308
Collections
Graduate School of Natural and Applied Sciences, Thesis
Suggestions
OpenMETU
Core
Appropriate passive cooling strategies for hot and humid climates : a case study in cyprus
Hançerli, Mustafa Yılmaz; Elias Özkan, Soofia Tahira; Department of Building Science in Architecture (2008)
In this study, energy conservation potential of appropriate passive cooling and basic heat avoidance strategies were investigated for hot and humid climates. Within this framework, thermal behavior of a case study building that is situated in Cyprus was assessed by collecting temperature and relative humidity data from various rooms of the building during certain days in August. Then, by using feasible simulation strategies of the software tool Summer-Building, the effectiveness of passive cooling measures ...
An investigation into the age-based thermal energy balance of occupied classrooms in primary schools
Taner, Özün; Düzgüneş, Arda; Department of Building Science in Architecture (2008)
The effect of indoor heat gain from occupants as a bio-thermal source was hypothetically assessed in terms of its contribution to overall heating requirements during such occupancy and hence to potential energy savings. The spaces considered were classrooms in a sample of 6 public co-educational primary schools located within the city limits of Ankara built after 1998, the date when compulsory primary education was integrated to encompass grades 1 through 8 for ages 6 to 14, respectively. Being so, this all...
An investigation on the lighting systems of the manufacturing floor in electronics industry
Kamoy, Leyla; Düzgüneş, Arda; Department of Building Science in Architecture (2010)
Required illumination levels in an electronics manufacturing facility were studied in order to provide feedback for architects and engineers. The study was carried out for the production floor of an electronics company in Ankara. The space considered was a Printed Circuit Board Assembly (PCBA) and Surface Mount Device (SMD) production department. The selected area was subdivided into different areas according to required illumination levels for each year. These levels were determined according to the specif...
The way architectural model as a new collaborative design environment talks with machines
Özkan, Sevda; Sorguç, Arzu; Department of Building Science in Architecture (2008)
The scope of this study is to illustrate the relationship between computer-aided design (CAD) and computer-aided manufacturing (CAM) systems, and to show how architectural modeling should be positioned in the process of computer-aided design/computer-aided manufacturing (CAD/CAM) systems. The integration of computer aided technologies with architectural design is investigated in terms of design-production/fabrication interaction. The research has been based on a case study in which the CAD/CAM process from ...
Assessing thermal comfort conditions: a case Study on the METU Faculty of Architecture building; the case of ODTÜKENT
Çakır, Çağrı; Elias Özkan, Soofia Tahira; Department of Building Science in Architecture (2006)
The aim of this study was to evaluate the effects of environmental design parameters on thermal comfort conditions in the METU Faculty of Architecture Building located in Ankara. The building had some problems in terms of indoor climatic conditions, both in winter and in summer. It was evident that some design parameters caused this undesirable situation. The study therefore focused on understanding and evaluating the effects of design-dependent elements such as thermal mass, the size and orientation of win...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
H. Kırmızı, “The effect of sun spaces on temperature patterns within buildings: two case studies on the METU campus,” M.S. - Master of Science, Middle East Technical University, 2009.