Appropriate passive cooling strategies for hot and humid climates : a case study in cyprus

Download
2008
Hançerli, Mustafa Yılmaz
In this study, energy conservation potential of appropriate passive cooling and basic heat avoidance strategies were investigated for hot and humid climates. Within this framework, thermal behavior of a case study building that is situated in Cyprus was assessed by collecting temperature and relative humidity data from various rooms of the building during certain days in August. Then, by using feasible simulation strategies of the software tool Summer-Building, the effectiveness of passive cooling measures in reducing energy consumption were examined, for summer months. In this context, the case study building was re-evaluated by applying natural ventilation, night ventilation and ground cooling strategies as well as solar control and shading devices as overhangs and side fins. Consequently, based on the results of the evaluation model, it was found that the proposed passive cooling strategies and basic heat avoidance concepts could provide more than 50 % energy conservation, relative to the completely air conditioned reference building, between 1-15 August 2007.

Suggestions

An investigation into the age-based thermal energy balance of occupied classrooms in primary schools
Taner, Özün; Düzgüneş, Arda; Department of Building Science in Architecture (2008)
The effect of indoor heat gain from occupants as a bio-thermal source was hypothetically assessed in terms of its contribution to overall heating requirements during such occupancy and hence to potential energy savings. The spaces considered were classrooms in a sample of 6 public co-educational primary schools located within the city limits of Ankara built after 1998, the date when compulsory primary education was integrated to encompass grades 1 through 8 for ages 6 to 14, respectively. Being so, this all...
The effect of sun spaces on temperature patterns within buildings: two case studies on the METU campus
Kırmızı, Hacer; Elias Özkan, Soofia Tahira; Department of Building Science in Architecture (2009)
The aim of this study was to investigate the passive and active parameters affecting energy efficiency of two office buildings with sun spaces, namely the MATPUM Building and the Solar Building on the Middle East Technical University (METU) Campus, Ankara and the effect of sun spaces on temperature patterns within mentioned buildings. Both buildings were oriented in the same direction, namely south. However, the location and the type of the sunspaces differed from each other. The sun space in the MATPUM Bui...
Evaluation of near-surface air temperature reanalysis datasets and downscaling with machine learning based Random Forest method for complex terrain of Turkey
Hasan Karaman, Çağrı; Akyürek, Sevda Zuhal (2023-01-01)
Near-surface air temperature is a key variable used in a wide range of applications showing the environmental conditions of the Earth. Standard meteorological observations generally provide the best estimation with high accuracy over time for a small area of influence. However, considerable uncertainty arises when point measurements are extrapolated or interpolated over much larger areas. Satellite and reanalysis products have emerged as a viable alternative or supplement to in situ observations due to thei...
Preventing claims in green construction projects through investigating the components of contractual and legal risks
Mohammadi, Sahra; Birgönül, Mustafa Talat (2016-12-15)
Construction sector has a great potential to reduce total energy consumption through the techniques applied in sustainable projects. All over the world, policy makers have already realized the potential and begun setting some governmental goals. Since new regulations for achieving sustainability have been recently set to change the conventionally practiced administrative patterns in construction sector, the number of claims related to sustainability features of the construction projects has been growing eve...
Theoretical investigation of a humidification-dehumidification desalination system configured by a double-pass flat plate solar air heater
Yamali, Cemil; Solmus, Ismail (Elsevier BV, 2007-02-05)
The aim of this study is to investigate theoretically the effect of different system operating conditions, types of air heater, and some different design parameters and a weather condition on a solar water desalination system performance under the climatological conditions of Ankara (40 degrees N,33 degrees E), Turkey. For this purpose, a computer simulation program based on the mathematical model is developed by means of MATLAB software. In this simulation program, the fourth order Runge-Kutta method is us...
Citation Formats
M. Y. Hançerli, “Appropriate passive cooling strategies for hot and humid climates : a case study in cyprus,” M.S. - Master of Science, Middle East Technical University, 2008.