Calibration of conventional measurement transformers against harmonic components by using field measurements of optical transducers and resistive-capacitive voltage transformers

Download
2010
Türkmen, Coşkun Aziz
It is known from the literature that conventional voltage and current transformers measure inaccurate values for voltage and current harmonics which are parts of power quality. Maximum bandwidth of conventional current transformers, which are used in electricity transmission and distribution systems, is 1.5-2 kHz and it is lower for conventional voltage transformers. Also, it is known that; voltages in some frequency spectrum are measured higher and voltages in another frequency spectrum are measured lower by the conventional voltage transformers. Furthermore, because of the phase shift of fundamental component caused by the conventional current and voltage transformers, losses and efficiency can not be calculated accurately. In this work, through the simultaneous measurements taken at the same feeder by both conventional transformers and new technology measurement transformers; amplitude and phase shift errors which are caused by conventional transformers depending on frequency and so harmonics, are examined and evaluated. Amplitude coefficients and phase shifts are determined for different types of conventional transformers to be able to calibrate measurement deviation. Through this work, measured data by conventional transformers will be accurate and realistic in terms of harmonic components. This matter is important to determine whether the accurate limits which will be set in the future possibly concerning with harmonics and interharmonics, are surpassed or not; also for punitive sanction.

Suggestions

Design and realization of a high voltage radio interference voltage (riv) measurement system
Özer, Mutlu; Hızal, Mirzahan; Department of Electrical and Electronics Engineering (2010)
This thesis aims the design and the realization of a radio noise meter which can be used to measure radio interference of a high-voltage transmission line due to partial discharges like conductor corona. The radio noise meter is the common equipment for radio noise and radio interference voltage measurements. The corona of transmission lines, its characteristics, its effects on radio interference and measurement of corona caused radio noise in the scope of relevant international standards are investigated. ...
Improvement of the electric field distribution in the medium voltage gas insulated inductive voltage transformers
Var, Melih; Keysan, Ozan; Department of Electrical and Electronics Engineering (2017)
IVoltage transformers are commonly used in medium voltage systems for both protection and measurement purposes. These transformers are designed to satisfy the mandatory IEC requirements at the lowest possible cost. The average life expectancy of such transformer is about 20 years, reliability and robustness are of the utmost importance. The main cause of failure during rated operation is the deterioration of the solid insulation by partial discharges. Partial discharges, unless there is a manufacturing erro...
Series active filter design, control, and implementation with a novel load voltage harmonic extraction method
Şentürk, Osman Selçuk; Hava, Ahmet Masum; Department of Electrical and Electronics Engineering (2007)
Series Active Filters (SAF) are designed for harmonic isolation and load voltage regulation of single-phase and three-phase voltage harmonic source type nonlinear loads. The novel Absolute Value Method (AVM) for load voltage harmonic extraction is proposed and applied in the control algorithm of SAF. The SAF compensated systems are represented by simplified linear models such that SAF controller gains can be easily determined. Harmonic isolation and load voltage regulation performances of 2.5 kW single-phas...
Optimizing transient and filtering performance of a C-type 2nd harmonic power filter by the use of solid-state switches
Gerçek, Cem Özgür; Ertaş, Arif; Department of Electrical and Electronics Engineering (2007)
In this research work, the performance of a C-type, 2nd harmonic power filter is optimized by the use of a thyristor switched damping resistor. In the design of conventional C-type, 2nd harmonic filters; the resistance of permanently connected damping resistor is to be optimized for minimization of voltage stresses on filter elements arising from switchings in transient state and for maximization of filtering effectiveness in the steady-state. Transformer inrush current during energization of power transfor...
Design and implementation of a voltage source converter based statcom for reactive power compensation and harmonic filtering
Çetin, Alper; Ermiş, Muammer; Department of Electrical and Electronics Engineering (2007)
In this thesis, design and implementation of a distribution-type, voltage source converter (VSC) based static synchronous compensator (D-STATCOM) having the simplest converter and coupling transformer topologies have been carried out. The VSC STATCOM is composed of a +/- 750 kVAr full-bridge VSC employing selective harmonic elimination technique, a low-pass input filter, and a /Y connected coupling transformer for connection to medium voltage bus. The power stage of VSC based STATCOM is composed of water-co...
Citation Formats
C. A. Türkmen, “Calibration of conventional measurement transformers against harmonic components by using field measurements of optical transducers and resistive-capacitive voltage transformers,” M.S. - Master of Science, Middle East Technical University, 2010.