Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Experimental and numerical analysis of a bolted connection in steel transmission towers
Date
2016-06-01
Author
Baran, Eray
Sen, Gokmen
Draisawi, Ammar
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
331
views
0
downloads
Cite This
This paper presents an integrated numerical and experimental study on a bolted splice connection used in main legs of steel lattice transmission towers. At specific locations, where the number of angle sections in built-up cross section of main leg members changes, the complex geometry around the connection region results in eccentricities in the load path and indirect load transfer. Such complex configurations and uncertainties in the load path have led to overdesigned connections with increased number of bolts and redundant connection reinforcing members. The current study was conducted in an attempt to gain a better understanding of the load-flow mechanism at this specific location where the cross section of main leg members changes. The experimental part included tensile load testing of six specimens with different connection details. The main parameters used in the testing program were the number of bolts used in the connection as well as the presence of connection reinforcement angles and tie plate. For all connection configurations studied, the failure occurred due to net section fracture of upper main member angle near leading bolt holes. The calculated load capacity based on the measured material strength closely predicted the measured load capacity of specimens. The experimentally determined response of each connection configuration was better predicted by the FE model that incorporates bolt slip as compared to the model that assumes no slip. The experimental and numerical results also indicate that major differences among the investigated connection details do not cause any appreciable difference in behavior under tensile loading.
Subject Keywords
Lattice transmission tower
,
Topic
,
Bolted connection
,
Splice connection
,
Steel angle
,
Bolt slip
,
Finite element analysis
,
Tension member
URI
https://hdl.handle.net/11511/33399
Journal
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH
DOI
https://doi.org/10.1016/j.jcsr.2016.02.009
Collections
Department of Civil Engineering, Article
Suggestions
OpenMETU
Core
Estimation of lining thickness around circular shafts
Ozturk, H; Unal, E (2001-06-22)
In this paper, the broken zone developing, around a circular mine shafts and lining pressure is estimated by integrating the results of numerical analysis and the "rock-load height" equation derived from empirical analysis. During numerical modelling studies, the computer program FLAC(2D) was utilized. In order to estimate equivalent Mohr failure Envelope from the generalised Hoek Brown failure criterion, a new FISH function was written within FLAC(2D). Parametric studies were carried out by considering mRM...
Optimum design of steel lattice transmission line towers using simulated annealing and PLS-TOWER
Tort, Cenk; Sahin, Serkan; Hasançebi, Oğuzhan (2017-01-15)
This paper presents a new optimization tool for automated design of steel lattice transmission line towers in real-world engineering practice. This tool has been developed by integrating the simulated annealing (SA) optimization algorithm into the commercial PLS-TOWER software to optimize steel lattice towers for minimum weight according to ASCE 10-97 design specification using both size and layout design variables. In this context, a novel two-phase SA algorithm is specifically developed and compared with ...
Application of Continuum Damage Mechanics in discontinuous crack formation: Forward extrusion chevron
Soyarslan, Celal; TEKKAYA, AHMET ERMAN; Akyüz, Uğurhan (2008-06-01)
Materializing Continuum Damage Mechanics (CDM), numerical modeling of discrete internal cracks, namely central bursts, in direct forward extrusion process is presented. Accordingly, in a thermodynamically consistent setting, a local Lemaitre variant damage model with quasi-unilateral evolution is coupled with hyperelastic-plasticity. The formulations are constructed in the principal axes where simultaneous local integration schemes are efficiently developed. To this end, the framework is implemented as ABAQ...
Numerical simulation of solidification kinetics in A356/SiCp composites for assessment of as-cast particle distribution
CETIN, Arda; Kalkanlı, Ali (Elsevier BV, 2009-06-01)
The present work is aimed at studying the effect of solidification rate on reinforcement clustering in particle reinforced metal matrix composites (PMMCs) through numerical simulations and experimental studies. A macrotransport-solidification kinetics (MTSK) model was used to simulate the solidification kinetics of the PMMCs. The experimental validation of the numerical model was achieved through the Newtonian and Fourier thermal analysis methods. Results reveal that the MTSK model can be successfully used ...
Numerical simulation of dynamic shear wall tests: A benchmark study
Kazaz, I; Yakut, Ahmet; Gulkan, P (2006-03-01)
This article presents the numerical simulation of a 1/3-scale, 5-story reinforced concrete load bearing structural wall model subjected to seismic excitations in the context of IAEA benchmark shaking table experiment conducted in laboratories of CEA in Saclay, France. A series of non-linear time history analyses were performed to simulate the damage experienced and response quantities measured for the specimen tested on a shaking table. The mock-up was subjected to a series of artificial and natural earthqu...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
E. Baran, G. Sen, and A. Draisawi, “Experimental and numerical analysis of a bolted connection in steel transmission towers,”
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH
, pp. 253–260, 2016, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/33399.