Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Output voltage control of a four-leg inverter based three-phase UPS by means of stationary frame resonant filter banks
Date
2007-05-05
Author
Demirkutlu, Eyyup
Cetinkaya, Sueleyman
Hava, Ahmet Masum
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
202
views
0
downloads
Cite This
A method for high performance output voltage control of a four-leg inverter (FLI) based three-phase UPS is proposed. Stationary frame resonant filter bank based output voltage control loop, which is complemented by capacitor current feedback based active damping loop, is employed. Utilizing the zero-state partitioning variable, a generalized form of scalar PWM for the FLI is developed and the minimum loss discontinuous PWM method is derived. The controller and modulator design and implementation details for the FLI-UPS are given. Linear and nonlinear loads for balanced and unbalanced load operating conditions are considered. The scalar control and PWM methods are proven by means of theory, simulations, and experiments.
Subject Keywords
Efficiency
,
Xwitching loss
,
UPS
,
Voltage regulation
,
Unbalance
,
Zero-sequence
,
Harmonic
,
THD
,
Crest factor
,
Resonant filter
,
Active damping
,
Scalar PWM
,
Zero-state partitioning
URI
https://hdl.handle.net/11511/38045
DOI
https://doi.org/10.1109/iemdc.2007.382785
Collections
Department of Electrical and Electronics Engineering, Conference / Seminar
Suggestions
OpenMETU
Core
Output voltage control of a four-leg inverter based three-phase UPS utilizing stationary frame resonant filter banks
Hava, Ahmet Masum (2007-09-05)
An all scalar PWM and control approach for the four-leg inverter based three phase transformerless UPS is proposed. The output voltage of each phase is controlled independently and its controller is formed by a stationary frame resonant filter bank accompanied with proportional control and output capacitor current based active damping loops. The resonant filter bank consists of the fundamental component controller and one controller for each dominant harmonic. The simple to implement scalar control method e...
Output voltage control of a four-leg inverter based three-phase ups by means of stationary frame resonant filter banks
Demirkutlu, Eyyüp; Hava, Ahmet Masum; Department of Electrical and Electronics Engineering (2006)
A method for high performance output voltage control of a four-leg inverter based three-phase transformerless UPS is proposed. Voltage control loop is employed and the method employs stationary frame resonant filter controllers for the fundamental and harmonic frequency components. A capacitor current feedback loop provides active damping and enhances the output voltage dynamic performance. The controller design and implementation details are given. Linear and nonlinear loads for balanced and unbalanced loa...
A Scalar Resonant-Filter-Bank-Based Output-Voltage Control Method and a Scalar Minimum-Switching-Loss Discontinuous PWM Method for the Four-Leg-Inverter-Based Three-Phase Four-Wire Power Supply
Demirkutlu, Eyyup; Hava, Ahmet Masum (2009-05-01)
An all-scalar-control and pulsewidth-modulation (PWM) approach for the four-leg-inverter (FLI)-based three-phase transformerless four-wire power supply (PS) is proposed. The output voltage of each phase is controlled independently, and its controller is formed by a stationary-frame resonant-filter bank accompanied with proportional-control and output-capacitor current-based active-damping loops. The simple and easy to implement scalar-control method exhibits superior overall steady state and dynamic perform...
Performance Characteristics of the Reduced Common Mode Voltage Near State PWM Method
Un, E.; Hava, Ahmet Masum (2009-07-01)
The Near State PWM (NSPWM) method, which has low common mode voltage and low common mode current, is proposed for three-phase voltage source inverter drives. The method is described and its voltage linearity, output current ripple, DC bus current ripple, common mode voltage and output line-to-line pulse patterns are thoroughly studied and compared with classical PWM methods. The theory, simulation, and laboratory experiments illustrate that in the high modulation index operating range NSPWM has superior ove...
Performance Evaluation and Selection of PWM Switching and Control Methods for Grid Connected Modular Multilevel Converters
Ciftci, Baris; Hava, Ahmet Masum (2015-09-24)
This paper focuses on the determination of suitable carrier based pulse width modulation (PWM) switching and control methods for grid connected modular multilevel converters (MMCs). Characterization of various level-shifted and phase-shifted carrier based PWM methods are provided in terms of output voltage waveforms both for N+1 and 2N+1 level output phase voltages. Carrier based PWM method based control approaches are evaluated for MMC. Performances of different control methods are evaluated and compared f...