Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Output voltage control of a four-leg inverter based three-phase UPS utilizing stationary frame resonant filter banks
Date
2007-09-05
Author
Hava, Ahmet Masum
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
204
views
0
downloads
Cite This
An all scalar PWM and control approach for the four-leg inverter based three phase transformerless UPS is proposed. The output voltage of each phase is controlled independently and its controller is formed by a stationary frame resonant filter bank accompanied with proportional control and output capacitor current based active damping loops. The resonant filter bank consists of the fundamental component controller and one controller for each dominant harmonic. The simple to implement scalar control method exhibits superior overall steady-state and dynamic performance in the UPS application. Utilizing the inverter zero-state partitioning, a generalized form of scalar PWM for the four-leg inverter is developed. A novel minimum loss discontinuous PWM (MLDPWM) method, which provides minimum switching losses under all operating conditions (including unbalanced load operation) is derived. This simple scalar method provides superior performance and unlike the vector methods it is easy to implement. The controller and modulator design and implementation details for the system are given. Linear and nonlinear loads for balanced and unbalanced load operating conditions are considered. The scalar control and PWM methods are proven by means of theory, simulations, and thorough laboratory experiments of a 5 kVA UPS system.
Subject Keywords
Zero sequence
,
Unbalanced load
,
Crest factor
,
THD
,
Harmonic
,
Dynamic response
,
Voltage regulation
,
Active damping
,
Filter bank
,
Resonant filter
,
Scalar control
,
Scalar PWM
,
VS
,
UPS
,
four-leg inverter
URI
https://hdl.handle.net/11511/36812
DOI
https://doi.org/10.1109/epe.2007.4417442
Conference Name
2007 European Conference on Power Electronics and Applications
Collections
Department of Electrical and Electronics Engineering, Conference / Seminar
Suggestions
OpenMETU
Core
Output voltage control of a four-leg inverter based three-phase UPS by means of stationary frame resonant filter banks
Demirkutlu, Eyyup; Cetinkaya, Sueleyman; Hava, Ahmet Masum (2007-05-05)
A method for high performance output voltage control of a four-leg inverter (FLI) based three-phase UPS is proposed. Stationary frame resonant filter bank based output voltage control loop, which is complemented by capacitor current feedback based active damping loop, is employed. Utilizing the zero-state partitioning variable, a generalized form of scalar PWM for the FLI is developed and the minimum loss discontinuous PWM method is derived. The controller and modulator design and implementation details for...
A Scalar Resonant-Filter-Bank-Based Output-Voltage Control Method and a Scalar Minimum-Switching-Loss Discontinuous PWM Method for the Four-Leg-Inverter-Based Three-Phase Four-Wire Power Supply
Demirkutlu, Eyyup; Hava, Ahmet Masum (2009-05-01)
An all-scalar-control and pulsewidth-modulation (PWM) approach for the four-leg-inverter (FLI)-based three-phase transformerless four-wire power supply (PS) is proposed. The output voltage of each phase is controlled independently, and its controller is formed by a stationary-frame resonant-filter bank accompanied with proportional-control and output-capacitor current-based active-damping loops. The simple and easy to implement scalar-control method exhibits superior overall steady state and dynamic perform...
Output voltage control of a four-leg inverter based three-phase ups by means of stationary frame resonant filter banks
Demirkutlu, Eyyüp; Hava, Ahmet Masum; Department of Electrical and Electronics Engineering (2006)
A method for high performance output voltage control of a four-leg inverter based three-phase transformerless UPS is proposed. Voltage control loop is employed and the method employs stationary frame resonant filter controllers for the fundamental and harmonic frequency components. A capacitor current feedback loop provides active damping and enhances the output voltage dynamic performance. The controller design and implementation details are given. Linear and nonlinear loads for balanced and unbalanced loa...
Output Ripple Performance Evaluation and Comparison of 2L-VSI and 3L-VSI Considering the Spectral Characteristics
Özkan, Ziya; Hava, Ahmet Masum (2015-06-05)
In this paper, two-level and three-level voltage source inverters (2/3L-VSIs) with popular pulse width modulation (PWM) methods are investigated in terms of their output (ac-side) voltage and current ripple spectral characteristics and waveform quality properties such as peak-to-peak ripple, rms ripple, and weighted total harmonic distortion. As the switching frequency and the filter size influence the output waveform quality, the inverter efficiency (loss) constraint on the switching frequency, and the siz...
Performance Evaluation and Selection of PWM Switching and Control Methods for Grid Connected Modular Multilevel Converters
Ciftci, Baris; Hava, Ahmet Masum (2015-09-24)
This paper focuses on the determination of suitable carrier based pulse width modulation (PWM) switching and control methods for grid connected modular multilevel converters (MMCs). Characterization of various level-shifted and phase-shifted carrier based PWM methods are provided in terms of output voltage waveforms both for N+1 and 2N+1 level output phase voltages. Carrier based PWM method based control approaches are evaluated for MMC. Performances of different control methods are evaluated and compared f...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
A. M. Hava, “Output voltage control of a four-leg inverter based three-phase UPS utilizing stationary frame resonant filter banks,” presented at the 2007 European Conference on Power Electronics and Applications, Aalborg, DENMARK, 2007, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/36812.