Proton irradiation and gamma-ray irradiation testing studies on the commercial grade GaNFETs to investigate their characteristics under the space radiation environment

Download
2019
Boyacı, Lütfi
In this thesis, the radiation performances of the commercial GaNFETs were investigated for the possible future integration of these devices to the power subsystems of the satellites as a main switching power element instead of the Silicon MOSFET. Two main irradiation tests were applied to the GaNFETs, namely proton irradiation test, and gamma-ray irradiation test. By these tests, tough space radiation environment was simulated to understand the GaNFET’s radiation performances. In the proton irradiation test, it is aimed to investigate the device’s performance of the Single Event Effect (SEE) which is the failure caused by the strike of the single high energetic particle. A GaNFET EPC2034 (200V, 48A) from Efficient Power Conversion Corporation (EPC) was chosen as a test sample considering the fact that it could be a possible candidate of the switch for the 100 V space bus designs. Four test samples were positioned on two test cards. They were irradiated with the 30 MeV protons while the devices are switching. A flux of 8.2x109 protons/cm2 /s is applied for 12.5 seconds for both test cards to reach ultimate fluence of 1011 protons/cm2 as declared in ESCC Specification No. 25100. Real-time measurements were taken. Vgs - Ids characteristics are measured and recorded for each device before, during and In this thesis, the radiation performances of the commercial GaNFETs were investigated for the possible future integration of these devices to the power subsystems of the satellites as a main switching power element instead of the Silicon MOSFET. Two main irradiation tests were applied to the GaNFETs, namely proton irradiation test, and gamma-ray irradiation test. By these tests, tough space radiation environment was simulated to understand the GaNFET’s radiation performances. In the proton irradiation test, it is aimed to investigate the device’s performance of the Single Event Effect (SEE) which is the failure caused by the strike of the single high energetic particle. A GaNFET EPC2034 (200V, 48A) from Efficient Power Conversion Corporation (EPC) was chosen as a test sample considering the fact that it could be a possible candidate of the switch for the 100 V space bus designs. Four test samples were positioned on two test cards. They were irradiated with the 30 MeV protons while the devices are switching. A flux of 8.2x109 protons/cm2 /s is applied for 12.5 seconds for both test cards to reach ultimate fluence of 1011 protons/cm2 as declared in ESCC Specification No. 25100. Real-time measurements were taken. Vgs - Ids characteristics are measured and recorded for each device before, during and after irradiation. It is observed that the devices retained their functionally. All the devices remained healthy and continued to operate. No failure was observed. Further irradiation is applied for one of the test cards (having two GaNFETs) with a destructive purpose. Same flux level is applied for 30 minutes up to a total fluence level of 1.476x1013 protons/cm2 which is quite higher level than that of appointed in the ESCC standard. It is observed that the GaNFETs stayed fully functional under this elevated level of radiation and no destructive events and irreversible failures took place for transistors. This study showed that the irradiated GaNFETs are reasonably resistant to applied proton radiation. In the gamma-ray irradiation test, the objective was to investigate the Total Ionizing Dose (TID), which corresponds to the cumulative radiation effect, performance of the devices. Two test samples were chosen, EPC2034 and GS61004B (100 V - 45 A) from GaN Systems, respectively. GS61004B was considered as a possible candidate of switch for the 28 V or 50 V power system buses. Nine irradiation test samples for each brand were assembled to two irradiation boards separately. In each board, three of the devices were biased from gate to source, three of them were biased from drain to source and the remaining three were unbiased to observe the bias effects on the device’s radiation performance. The radiation dose was adjusted to 12,5 kRad (Si)/hour. Measurements were taken for the levels of 12.5, 25, 50 and 100 kRad respectively between the 1, 1, 2, and 4 hours of gamma-ray irradiation intervals. Gate to source voltages, drain to source voltages and drain current waveforms were recorded for the switching periods. Gate to source threshold voltages, gate to source plateau voltages, gate to source rise and fall times, and drain to source rise and fall times were analyzed for each device under test in detail. All the 18 devices stayed healthy and fully operational. No irreversible or destructive effects were observed. No meaningful or one-way change was noticed on the devices’ gate to source threshold voltages and plateau voltages or rise and fall times. Characteristics and the performances of the devices have not changed. It was clearly observed that the irradiated samples were radiation-resistant up to a total dose level of 100 kRad regardless of the bias condition.

Suggestions

Installation of the METU Defocusing Beamline to Perform Space Radiation Tests
Demirköz, Melahat Bilge; Poyrazoglu, Anil Berkay; Seckin, Caner; Uslu, Pelin; Celik, Nazire; Bulbul, Besna; Albarodi, Abdulrahman; Akcelik, Selen; Orhan, Yusuf; Avaroglu, Akanay; Kilic, Erinc; Saral, Caglar; Duran, Selcen Uzun; Yigitoglu, Merve (2019-01-01)
METU Defocusing Beamline (DBL) is being installed at TAEA SANAEM Proton Accelerator Facility [1] for radiation tests of electronic devices to be used in satellites and spacecrafts which are exposed to a high radiation dose in space or at the Hi-Lumi LHC [2]. 15 - 30 MeV protons from the accelerator are spread out over an area of 15.40 X 21.55 cm to provide large irradiation in accordance to ESA/ESCC No. 25100 standard with METU-DBL. A wide selectable flux menu ranging from 10(5) - 10(10) p/cm(2)/s will be a...
Frequency Modulated Raman Spectroscopy
Greco, Silvio; Dal Zilio, Simone; Bek, Alpan; Lazzarino, Marco; Naumenko, Denys (2018-02-01)
The coupling of plasmonic and mechanical properties at the nanoscale is of great potential for the development of next generation devices capable to detect weak forces, mass changes, minute displacements and temperature induced effects. Both the transduction of mechanical motion to the scattered light fields in term of polarization or intensity modulation and plasmon-driven mechanical oscillations have already been demonstrated. Quasi static tunable hot spots have recently been designed and applied to surfa...
Radiation pressure excitation of a low temperature atomic force/magnetic force microscope for imaging in 4-300 K temperature range
Celik, Umit L; KARCI, Ozgur; UYSALLI, Yigit; Özer, Hakkı Tunçay; Oral, Ahmet (2017-01-01)
We describe a novel radiation pressure based cantilever excitation method for imaging in dynamic mode atomic force microscopy (AFM) for the first time. Piezo-excitation is the most common method for cantilever excitation, however it may cause spurious resonance peaks. Therefore, the direct excitation of the cantilever plays a crucial role in AFM imaging. A fiber optic interferometer with a 1310 nm laser was used both for the excitation of the cantilever at the resonance and the deflection measurement of the...
Metu-Defocusing Beamline : A 15-30 Mev Proton Irradiation Facility and Beam Measurement System
Demirköz, Melahat Bilge; Akanay, Avaroğlu; Besna, Bülbül; Pelin, Uslu; Erinç, Kılıç; Yusuf, Orhan; Selen, Akçelik; Merve, Yiğitoğlu; Çağlar, Saral; Uzun Duran, Selcen; Kılıç, Uğur; İlias, Efthymiopoulos; Anıl Berkay, Poyrazoğlu; Abdrahman, Albarodi; Nazire, Çelik (2020-01-01)
Middle East Technical University – Defocusing Beam Line (METU-DBL) project is an irradiation facility providing 15 MeV to 30 MeV kinetic energy protons for testing various high radiation level applications, ranging from Hi-Lumi LHC upgrade, space electronic components to nuclear material research. The project located inside the premises of the TAEA (Turkish Atomic Energy Agency) SANAEM (Saraykoy Nuclear Education and Research Center) close to Ankara, provides users a wide selectable flux menu (105–1010 p/cm...
Defocusing beam line design for an irradiation facility at the TAEA SANAEM Proton Accelerator Facility
Gencer, A.; Demirköz, Melahat Bilge; Efthymiopoulos, I.; Yigitoglu, M. (2016-07-11)
Electronic components must be tested to ensure reliable performance in high radiation environments such as Hi-Limu LHC and space. We propose a defocusing beam line to perform proton irradiation tests in Turkey. The Turkish Atomic Energy Authority SANAEM Proton Accelerator Facility was inaugurated in May 2012 for radioisotope production. The facility has also an R&D room for research purposes. The accelerator produces protons with 30 MeV kinetic energy and the beam current is variable between 10 mu A and 1.2...
Citation Formats
L. Boyacı, “Proton irradiation and gamma-ray irradiation testing studies on the commercial grade GaNFETs to investigate their characteristics under the space radiation environment,” Thesis (M.S.) -- Graduate School of Natural and Applied Sciences. Electrical and Electronics Engineering., Middle East Technical University, 2019.