Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
How do annuloplasty rings affect mitral leaflet dynamic motion?
Download
index.pdf
Date
2010-09-01
Author
Bothe, Wolfgang
Kvitting, JPE
Swanson, Julia
Göktepe, Serdar
Vo, Kathy
Ingels, Neil
Miller, Craig
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
274
views
0
downloads
Cite This
Objectives: To define the effects of annuloplasty rings (ARs) on the dynamic motion of anterior mitral leaflet (AML) and posterior mitral leaflet (PML). Methods: Fifty-eight adult, Dorsett-hybrid, male sheep (49 5 kg) had radiopaque markers inserted: eight around the mitral annulus, four along the central meridian (from edge to annulus) of the AML (#A(1)-#A(4)) and one on the PML edge (#P-1). True-sized Edwards Cosgrove (COS, n = 12), St Jude RSAR (St. Jude Medical, St. Paul, MN, USA) (n = 12), Carpentier-Edwards Physio (PHYSIO, n = 12), Edwards IMR ETlogix (ETL, n = 10) or Edwards GeoForm (GEO, n = 12) ARs were implanted in a releasable fashion. Under acute open-chest conditions, 4D marker coordinates were obtained using biplane videofluoroscopy with the respective AR inserted (COS, RSAR, PHYSIO, ETL and GEO) and after release (COS-Control, RSAR-Control, PHYSIO-Control, ETL-Control and GEO-Control). AML and PML excursions were calculated as the difference between minimum and maximum angles between the central mitral annular septal-lateral chord and the AML edge markers (alpha(1exc)-alpha(4exc)) and PML edge marker (beta(1exc)) during the cardiac cycle. Results: Relative to Control, (1) RSAR, PHYSIO, ETL and GEO increased excursion of the AML annular (alpha(4exc): 13 +/- 6 vs 16 +/- 70 degrees(star), 16 +/- 7 degrees vs 23 +/- 10 degrees(star), 12 +/- 4 degrees vs 18 +/- 9 degrees(star), 15 +/- 10 degrees(star) vs 20 +/- 9 degrees(star), respectively) and belly region (alpha(2exc): 41 +/- 10 degrees(star) vs 45 +/- 10 degrees(star), 42 +/- 8 degrees vs 45 +/- 6, n.s., 33 +/- 13 degrees vs 42 +/- 14 degrees(star), 39 +/- 6 degrees(star) vs 44 +/- 60 degrees(star), respectively, alpha(3exc): 24 +/- 9 degrees vs 29 +/- 11 degrees(star), 28 +/- 10 degrees vs 33 +/- 10 degrees(star), 16 +/- 9 degrees vs 21 +/- 12 degrees(star), 25 +/- 7 degrees vs 29 +/- 9 degrees(star), respectively), but not of the AML edge (alpha(1exc): 42 +/- 8 degrees(star) vs 44 +/- 8 degrees, 43 +/- 8 degrees vs 41 +/- 6 degrees, 42 +/- 11 vs 46 +/- 10 degrees, 39 +/- 9 degrees vs 38 +/- 8 degrees, respectively, all n.s.). COS did not affect AML excursion (ale c: 40 +/- 8 degrees vs 37 +/- 8 degrees, alpha(2exc): 43 +/- 9 degrees vs 41 +/- 9 degrees, alpha(3exc): 27 +/- 11 degrees vs 27 +/- 10 degrees, alpha(4exc): 18 +/- 8 degrees vs 17 +/- 7 degrees, all n.s.). (2) PML excursion (file,x) was reduced with GEO (53 5 vs 43 60*), but unchanged with COS, RSAR, PHYSIO or ETL (53 13 vs 52 150, 50 13 vs 49 + 10, 55 + 5 vs 55 7, 52 8 vs 58 6, respectively, all n.s); star = p < 0.05. Conclusions: RSAR, PHYSIO, ETL and GEO rings, but not COS, increase AML excursion of the AML annular and belly region, suggesting higher anterior mitral leaflet bending stresses with rigid rings, which potentially could be deleterious with respect to repair durability. The decreased PML excursion observed with GEO could impair left ventricular filling. Clinical studies are needed to validate these findings in patients. (C) 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Subject Keywords
Surgery
,
Pulmonary and Respiratory Medicine
,
Cardiology and Cardiovascular Medicine
,
General Medicine
URI
https://hdl.handle.net/11511/44200
Journal
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY
DOI
https://doi.org/10.1016/j.ejcts.2010.02.011
Collections
Department of Civil Engineering, Article
Suggestions
OpenMETU
Core
Evaluation of 3D printed carotid anatomical models in planning carotid artery stenting
Gocer, Hakan; Durukan, Ahmet Baris; Tunc, Osman; Naseri, Erdinc; Ercan, Ertugrul (Baycinar Tibbi Yayincilik, 2020-04-01)
Background: We aimed to investigate the potential role of three-dimensional printed anatomical models in pre-procedural planning, practice, and selection of carotid artery stent and embolic protection device size and location.
Analysis of factors affecting baseline SF-36 Mental Component Summary in Adult Spinal Deformity and its impact on surgical outcomes
Mmopelwa, Tiro; Ayhan, Selim; Yuksel, Selcen; Nabiyev, Vugar; Niyazi, Asli; Pellise, Ferran; Alanay, Ahmet; Sanchez Perez Grueso, Francisco Javier; Kleinstuck, Frank; Obeid, Ibrahim; Acaroglu, Emre (AVES Publishing Co., 2018-5)
Objectives: To identify the factors that affect SF-36 mental component summary (MCS) in patients with adult spinal deformity (ASD) at the time of presentation, and to analyse the effect of SF-36 MCS on clinical outcomes in surgically treated patients. Methods: Prospectively collected data from a multicentric ASD database was analysed for baseline parameters. Then, the same database for surgically treated patients with a minimum of 1-year follow-up was analysed to see the effect of baseline SF-36 MCS on t...
Anterior Mitral Leaflet Curvature During the Cardiac Cycle in the Normal Ovine Heart
Kvitting, JPE; Bothe, Wolfgang; Göktepe, Serdar; Rausch, Manuel; Swanson, Julia; Kuhl, Ellen; Ingels, Neil; Miller, Craig (Ovid Technologies (Wolters Kluwer Health), 2010-10-26)
Background-The dynamic changes of anterior mitral leaflet (AML) curvature are of primary importance for optimal left ventricular filling and emptying but are incompletely characterized.
A Novel Method to Adjust Saphenous Vein Graft Lengths Using 3D Printing Models
Gocer, Hakan; Durukan, Ahmet Baris; Tunc, Osman; Naseri, Erdinc; Ercan, Ertugrul (Carden Jennings Publishing Co., 2020-01-01)
Background: The optimal length of saphenous vein grafts can be challenging in surgical coronary revascularization. It is the cornerstone for graft patency. In this study, we tried to demonstrate the value of 3D printing in determining optimal saphenous graft length.
Simultaneous mapping of endocardium and epicardium from multielectrode intrachamber and intravenous catheters: a computer simulation-based validation
Baysoy, Engin; Cunedioglu, Ugur; Yilmaz, Buelent (Elsevier BV, 2010-01-01)
A multielectrode basket-shaped contact catheter (MBC) provides simultaneous recordings of unipolar or bipolar electrograms from within the heart chambers Another catheter-based mapping approach uses the multielectrode intravenous catheters (MIVCs), which are widely used to diagnose and treat supraventricular arrhythmias It is also known that mapping techniques are usually limited to one surface at a time Therefore, an approach that can be used for simultaneous mapping of left and right endocardial surfaces ...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
W. Bothe et al., “How do annuloplasty rings affect mitral leaflet dynamic motion?,”
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY
, pp. 340–349, 2010, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/44200.