Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Accuracy of a manual torque application device for morse-taper implants: A technical note
Date
2004-09-01
Author
CEHRELI, Murat Cavit
AKCA, Kıvanç
Tönük, Ergin
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
140
views
0
downloads
Cite This
Purpose: The objective of this study was to compare torques applied by new and used manual torque devices for Morse-taper implants. Material and Methods: Fifteen ITI manual torque devices were tested. Those in group 1 (n = 5) were new (ie, never used), those in group 2 (n = 5) had been used 50 to 200 times, and those in group 3 (n = 5) had been used 500 to 1,000 times. The torques applied by each device were measured for 35 Ncm and 15 Ncm targets in an experimental setup by a custom-made wrench with strain gauges connected to a data acquisition system. The strain-gauge signals were simultaneously delivered to a computer at a sample rate of 10,000 Hz and converted to torque units. Results: New devices applied higher torques than used devices for the 35-Ncm torque target (P < .05). The torques applied by group 3 devices were approximately 1.5 Ncm lower than those of other groups for the 35-Ncm target and approximately 1 Ncm lower for the 15-Ncm target. Discussion and Conclusion: ITI manual torque devices deliver consistent torque output, although a slight decrease occurs as a consequence of clinical use.
Subject Keywords
Dental implants
,
Manual torque devices
,
Preload
,
Screw mechanics
,
Torque
URI
https://hdl.handle.net/11511/54577
Journal
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS
Collections
Department of Mechanical Engineering, Article
Suggestions
OpenMETU
Core
Setup for testing the vibration-based loosening of pre-loaded bolted joints
Cavdar, F. Yildiz; Bilal, Halil; Güllü, Ramazan; Güler, Birtan; Ciğeroğlu, Ender; Cavdar, Kadir; Solmaz, Erol (Carl Hanser Verlag, 2019-01-01)
In this study, a test setup was designed and manufactured in order to study vibration based self-loosening characteristics of preloaded bolted joints, especially used in the automobile industry. Details of the designed test setup and its operating principles are presented in addition to the test setups available in the literature. Using the test system developed and implementing a design of experiments procedure, first trials were conducted by using the test setup. Under predefined conditions, it is possibl...
Optimization of Tooth Bending Fatigue Characteristics of Spur Gear Pairs using a Gear Dynamics based Approach
ÖZTÜRK, YALIN; Ciğeroğlu, Ender; Özgüven, Hasan Nevzat (2015-08-05)
A gear tooth profile optimization study is performed with the target being defined as the maximization of tooth bending fatigue life for a selected operational range, where the operating torque and speed ranges are defined along with their corresponding durations. For this purpose, a nonlinear lumped gear dynamics model is combined with the S/N curve of the gear material in order to estimate tooth bending fatigue life of the spur gear pair. The differences between the predicted lives of the optimally modifi...
Comparison of magnetic Barkhausen noise and ultrasonic velocity measurements for microstructure evaluation of SAE 1040 and SAE 4140 steels
Gür, Cemil Hakan; Çam, İbrahim (Elsevier BV, 2007-05-01)
The aim of this study is to compare the performance of magnetic Barkhausen noise and ultrasonic methods for the evaluation of the microstructure of commercial steels. Following the austenitization of the specimens made of SAE 1040 and SAE 4140, various heat treatments were carried out to obtain microstructures consisting of martensite, tempered martensite, fine pearlite-ferrite, and coarse pearlite-ferrite. The microstructures were initially characterized by SEM investigation and hardness measurements. The ...
Frictionless double contact problem for an axisymmetric elastic layer between an elastic stamp and a flat support with a circular hole
Mert, Oya; Geçit, M. Ruşen; Department of Engineering Sciences (2011)
This study considers the elastostatic contact problem of a semi-infinite cylinder. The cylinder is compressed against a layer lying on a rigid foundation. There is a sharp-edged circular hole in the middle of the foundation. It is assumed that all the contacting surfaces are frictionless and only compressive normal tractions can be transmitted through the interfaces. The contact along interfaces of the elastic layer and the rigid foundation forms a circular area of which outer diameter is unknown. The probl...
Comparison of Matrix Converter Induction Motor Drive Control Methods
Lettl, Jiri; Kuzmanovic, Dragan; Fligl, Stanislav (2011-09-10)
In this paper, the implementation of the Field Oriented Control and the Direct Torque Control in matrix converter supplied induction motor drives is analysed, and compared with the implementation in drives supplied by the Voltage Source Inverter. The analysis is accompanied by the results of numerical simulations and experimental implementations of these two control methods.
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
M. C. CEHRELI, K. AKCA, and E. Tönük, “Accuracy of a manual torque application device for morse-taper implants: A technical note,”
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS
, pp. 743–748, 2004, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/54577.