AN INTERFEROMETRIC TECHNIQUE FOR MEASURING MICRON LEVEL CLEARANCES FILLED WITH A LUBRICANT
Date
2010-10-20
Author
Yildirim, Murat
Dursunkaya, Zafer
Okutucu Özyurt, Hanife Tuba
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
0
views
0
downloads
The aim of this study is to develop an interferometric technique to measure micron level clearances occurring in small piston-cylinder arrangements; such as hermetically sealed compressors. A Cartesian model of the piston cylinder arrangement is manufactured and lateral and vertical motions are generated via a step motor, and micrometers, respectively, to simulate the piston motion and the change of clearance during the motion. Experiments are conducted in air and a lubricant. Measurements show the important effect of surface waviness of the mirror and the effect of the motion of the carriage at micron level measurements.