Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
A New Phase Measurement Technique for RF Power Amplifier Only Measuring Magnitudes
Date
2010-07-08
Author
Yuzer, A. H.
Demir, Şimşek
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
154
views
0
downloads
Cite This
In this study, a new phase measurement setup to measure magnitudes and phases of the fundamental components and intermodulation created by an amplifier under two tone excitation is reported. There are three signal generators, one digital attenuator and one spectrum analyzer in the measurement setup. There is no need to any other special electronic circuits (e.g., mixer, filter, etc.). Phase is found/measured mathematically based on magnitude measurements. Also absolute phase difference between the frequency components can be measured. Measured phase error is better than 1 degrees for repetitive measurements.
URI
https://hdl.handle.net/11511/55978
Conference Name
Progress in Electromagnetics Research Symposium
Collections
Department of Electrical and Electronics Engineering, Conference / Seminar
Suggestions
OpenMETU
Core
A new technique for line interference monitoring and reduction in biopotential amplifiers
Ider, Yusuf Ziya; Koymen, H. (Institute of Electrical and Electronics Engineers (IEEE), 1990-6)
Hardware developed to record the common mode line frequency signal on the body simultaneously with the ECG lead signals of a 15-channel computerized cardiograph is described. This interference reference signal and its quadrature, obtained by software, are linearly combined to be subtracted from any one of the channels to reduce the interference to below the quantization level of the 12 b A/D converter. Coefficients of the linear combination are estimated using linear regression, which is applied to the rela...
A Novel Software for Automatic Calibration Factor Measurement of RF Power Sensors
Kizilbey, Oguzhan; Arslan, Murat; Bayrak, Yusuf; Çetinkaya, Anıl; Yugruk, Aydin; Danaci, Erkan (2022-01-01)
In this letter, a software for calibration factor (CF) measurement of radio frequency (RF) power sensors (PS) by using VNA-based direct comparison transfer method (VBDCTM) was developed on C# platform. Measurements were performed between 10 MHz and 18 GHz frequency range. When the calibration factors calculated with conventional CF measurement method and novel software were compared, a maximum difference of 4.56% was found in the 10 MHz - 18 GHz frequency band. Therefore, the automatic CF measurement softwa...
A New Approach to Investigation of the Relationship of VLF Signals by Using Longitudinal Analysis Models
Guzel, E.; Yaşar, M.; Kılıç, M. B.; Canyılmaz, M. (Hindawi Limited, 2013)
Longitudinal analysis models are applied to analyze very low frequency (VLF) electromagnetic waves signals. They are useful in realization of nuance of relationship between parameters of concern which change over time. VLF data are so important for the communication and determining the disturbances in the lower ionosphere. In this study, we used a four-day VLF signal data which come from transmitter stations located at two different countries to Elazi. g receiver system. A very important feature of this dat...
A novel approach for synthesising sinus waveforms at power level
Şedele, Serkan Paki; Ertan, Hulusi Bülent; Department of Electrical and Electronics Engineering (2004)
In variable speed motor drive and uninterruptible power supply (UPS) applications, taditional method is to employ some kind of a modulation technique at a high frequency typically 6 kHz to 20 kHz range. In these modulation techniques, the switches are hard switched. The result is application of a series of pulses to the load, and if the load is inductive, sine wave current flows into the load. Hard and rapid switching causes a voltage waveform with a very high dv/dt (rate of change in voltage) causing high ...
A Novel Characterization Method for MEMS Based Electrostatic Resonators for Q Enhancement and Feedthrough Current Elimination
AYDIN GÖL, EBRU; Kangul, M.; Gökce, Fuat; Zorlu, O.; Külah, Haluk (2016-11-03)
This paper introduces a new technique for electrostatic resonance characterization based on 2nd harmonic distortion terms at the output current. Mathematical analysis of the output current shows that the 2nd harmonic component exhibits higher quality factor (Q) than the 1st harmonic. Besides, output current to feedthrough current ratio is higher in the 2nd harmonic term. Experimental results show that the Q of the resonating system is enhanced by 66% with 2nd harmonic operation. Moreover, the resonance peak...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
A. H. Yuzer and Ş. Demir, “A New Phase Measurement Technique for RF Power Amplifier Only Measuring Magnitudes,” presented at the Progress in Electromagnetics Research Symposium, Cambridge, MA, 2010, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/55978.