Prolonged reuse of domestic wastewater after membrane bioreactor treatment

2015-03-20
KOMESLİ, Okan Tarık
Muz, Melis
Ak, Selcen
Gökçay, Celal Ferdi
In this study, experience in a nine-year operation of a full-scale 2000 PE vacuum rotating membrane bioreactor having a submerged flat-type membrane module having pore size of 0.038 mu m and a total surface area of 540 m(2) is discussed. The plant was designed to treat and reuse raw wastewater collected from dormitories and the academic village at METU campus. Throughout the study, 99.99% BOD5 and above 95% COD removals were achieved most of the time. Moreover, turbidity was consistently measured below 1 NTU and around 6-7 log coliform removals were achieved with less than 1 coliform/100 mL in the effluents most of the time, except for the leakage from the bearings. During the study, energy consumption by the plant was also analyzed by routinely measuring energy consumption in different parts of the plant. Consumption was analyzed in two parts. Energy consumed by the blower supplying aeration to the biological treatment tank was monitored separately from the rest of the plant. Except for the periods when problems have occurred during operation, the total energy consumption of the system was variable between 1.1 and 2.53 kWh/m(3), averaging around 2 kWh/m(3). The main problems encountered during operation were poor floc formation and dispersed growth, and sludge deposition between the membrane plates and mechanical malfunction of the bearing seals. The treated wastewaters were stored and used for the irrigation of METU Technopolis lawns.
DESALINATION AND WATER TREATMENT

Suggestions

Electro-chemo-mechanical induced fracture modeling in proton exchange membrane water electrolysis for sustainable hydrogen production
Aldakheel, Fadi; Kandekar, Chaitanya; Bensmann, Boris; Dal, Hüsnü; Hanke-Rauschenbach, Richard (2022-10-01)
This work provides a framework for predicting fracture of catalyst coated membrane (CCM) due to coupled electro-chemo-mechanical degradation processes in proton exchange membrane water electrolysis (PEMWE) cells. Electrolysis in the catalyst layer (CL) bulk, diffusion of Hydrogen proton through the membrane (MEM), and mechanical compression at the interface with the porous transport layer (PTL) generate micro-cracks that influence the catalyst degradation. Based on our experimental observations, we propose ...
Improvement of PEMFC performance with Nafion/inorganic nanocomposite membrane electrode assembly prepared by ultrasonic coating technique
Devrim, Yilser; Erkan, Serdar; BAÇ, NURCAN; Eroğlu, İnci (2012-11-01)
electrode assemblies with Nafion/nanosize titanium silicon dioxide (TiSiO4) composite membranes were manufactured with a novel ultrasonic-spray technique and tested in proton exchange membrane fuel cell (PEMFC). Nafion/TiO2 and Nafion/SiO2 nanocomposite membranes were also fabricated by the same technique and their characteristics and performances in PEMFC were compared with Nafion/TiSiO4 mixed oxide membrane. The composite membranes have been characterized by thermogravimetric analysis, scanning electron m...
Tamoxifen-model membrane interactions: An FT-IR study
Boyar, H; Severcan, Feride (1997-06-01)
The temperature- and concentration-induced effects of tamoxifen (TAM) on dipalmitoyl phosphatidylcholine (DPPC) model membranes were investigated by the Fourier transform-infrared (FT IR) spectroscopic technique. An investigation of the C-H stretching region and the C=0 mode reveals that the inclusion of TAM changes the physical properties of the DPPC multibilayers by (i) shifting the main phase transition to lower temperatures; (ii) broadening the transition profile slightly; (iii) disordering the system i...
Broadband THz Modulators Based on Multilayer Graphene on PVC
KAYA, Emine; Kakenov, Nurbek; Kocabas, Coskun; Altan, Hakan; Esentürk, Okan (2016-09-30)
In this study we present the direct terahertz timedomain spectroscopic measurement of CVD-grown multilayer graphene (MLG) on PVC substrate with an electrically tunable Fermi level. In a configuration consisting MLG and injected organic dopant, the transmitted intensity loss of terahertz radiation was observed with an applied voltage between 0 and 3.5 V.We showed that MLG on PVC devices provided approximately 100 % modulation between 0.2 and 1.5 THz at preferentially low operation voltage of ca. 3V. The obse...
Non-contact atomic force microscope in ultra high vacuum using radiation pressure excitation of cantilever with Fabry-Perot interferometer
Karagöz, Ercan; Oral, Ahmet; Department of Physics (2017)
In this study Non-Contact Atomic Force Microscope (NC-AFM) imaging was performed by excitation of the cantilever via radiation pressure in a custom Ultra-High Vacuum (UHV) system. Both the excitation of the cantilever and the measurement of the deflection of the cantilever were done by employing a fiber Fabry-Pérot interferometer obtained by a TiO2 coating of the fiber end. This coating allows for a several times higher interference slope. The second normal mode of the cantilever oscillation, along with the...
Citation Formats
O. T. KOMESLİ, M. Muz, S. Ak, and C. F. Gökçay, “Prolonged reuse of domestic wastewater after membrane bioreactor treatment,” DESALINATION AND WATER TREATMENT, pp. 3295–3302, 2015, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/56541.