Spectral analysis of T wave alternans signal

1996-11-03
Serinagaoglu, Y
Sabuncuoglu, D
Ider, YZ
T wave alternans signal was obtained from a patient who recently recovered from ventricular fibrillation. The power spectrum of the T wave alternans is computed using an Autoregressive model based technique. The signal is found to be a sinusoid at a frequency equal to the half of the heart rate and amplitude modulated with another sinusoid at a lower frequency. Relation between the spectrums of the T wave alternance signal and the RR variation signal is also discussed.

Suggestions

Parkinsonian Rest Tremor Is Associated With Modulations of Subthalamic High-Frequency Oscillations
Hirschmann, Jan; Butz, Markus; Hartmann, Christian J.; Hoogenboom, Nienke; Özkurt, Tolga Esat; Vesper, Jan; Wojtecki, Lars; Schnitzler, Alfons (2016-10-01)
BackgroundHigh frequency oscillations (>200 Hz) have been observed in the basal ganglia of PD patients and were shown to be modulated by the administration of levodopa and voluntary movement.
Pulse phase resolved x-ray spectroscopy of four accretion powered millisecond pulsars
Çolak, Sıdıka Merve; Baykal, Altan; Department of Physics (2014)
In this thesis, pulse phase resolved X-ray spectroscopy of four accretion powered millisecond pulsars which are IGR J00291+5934 , IGR J17498-2921 , XTE J0929-314 and XTE J1807-294 will be presented. Phase dependent changes during their outbursts will be checked for possible correlations of spectral parameters such as photon index and blackbody temperature with rotation phase using archive of Rossi X-ray Timing Explorer (RXTE) observations. In the analysis of IGR J17498-2921 in 2011 outburst , positive corre...
STATISTICAL MODELING OF THE GEOMETRIC ERROR IN CARDIAC ELECTRICAL IMAGING
Aydin, Umit; Serinağaoğlu Doğrusöz, Yeşim (2009-07-01)
Kalman filter approach provides a natural way to include the spatio-temporal prior information in cardiac electrical imaging. This study focuses on the performance of Kalman filter approach with geometric errors present in inverse Electrocardiography (ECG) problem. The geometric errors considered here are the wrong determination of the heart's size and location. In addition to Kalman filtering, we also compare the performances of Tikhonov regularization and Bayesian MAP estimation when geometric errors are ...
Analysis of magnetic resonance imaging in inhomogenous main magnetic field
Arpınar, Volkan Emre; Eyüboğlu, Behçet Murat; Department of Electrical and Electronics Engineering (2009)
In this study, analysis of Magnetic Resonance Imaging (MRI) in inhomogeneous main magnetic field is conducted. A numerical model based on Bloch equation is implemented for MRI, to understand effect of inhomogeneous magnetic field to Magnetic Resonance (MR) signal. Using the model, relations between inhomogeneity levels in main magnetic field with energy, decay time, bandwidth of the FID signal is investigated. Also relation between the magnetic field inhomogeneity and field of view is determined. To simulat...
Measurement of AC magnetic field distribution using magnetic resonance imaging
Ider, YZ; Muftuler, LT (1997-10-01)
Electric currents are applied to body in numerous applications in medicine such as electrical impedance tomography, cardiac defibrillation, electrocautery, and physiotherapy. If the magnetic field within a region is measured, the currents generating these fields can be calculated using the curl operator. In this study, magnetic fields generated within a phantom by currents passing through an external wire is measured using a magnetic resonance imaging (MRI) system, A pulse sequence that is originally design...
Citation Formats
Y. Serinagaoglu, D. Sabuncuoglu, and Y. Ider, “Spectral analysis of T wave alternans signal,” 1996, vol. 18, p. 1353, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/66364.