High Throughput Parylene Micro-Channel Coulter Counter For Parallel Cell Counting and Sorting

2014-07-16
Sümer Laçin, Özgen
Demircan Yalçın, Yağmur
Zorlu, Özge
Özgür, Ebru
Gündüz, Ufuk
Külah, Haluk
Erdem, Murat

Suggestions

High performance non-binary spatially-coupled codes for flash memories
Hareedy, Ahmed; Esfahanizadeh, Homa; Dolecek, Lara (2018-01-31)
Modern dense Flash memory devices operate at very low error rates, which require powerful error correcting coding (ECC) techniques. An emerging class of graph-based ECC techniques that has broad applications is the class of spatially-coupled (SC) codes, where a block code is partitioned into components that are then rewired multiple times to construct an SC code. Here, our focus is on SC codes with the underlying circulant-based structure. In this paper, we present a three-stage approach for the design of h...
High performance CMOS capacitive interface circuits for MEMS gyroscopes
Silay, Kanber Mithat; Akar, Tayfun; Department of Electrical and Electronics Engineering (2006)
This thesis reports the development and analysis of high performance CMOS readout electronics for increasing the performance of MEMS gyroscopes developed at Middle East Technical University (METU). These readout electronics are based on unity gain buffers implemented with source followers. High impedance node biasing problem present in capacitive interfaces is solved with the implementation of a transistor operating in the subthreshold region. A generalized fully differential gyroscope model with force feed...
High performance closed-loop analog readout circuit for capacitive MEMS accelerometers
Terzioğlu, Yunus; Akın, Tayfun; Department of Electrical and Electronics Engineering (2015)
In this thesis, a closed-loop analog readout circuit for capacitive MEMS accelerometers is introduced. The detailed analysis of the dynamics of the proposed accelerometer is presented along with the associated simulation models. The theoretical investigation of each building block of the accelerometer is also presented in detail and supported by the corresponding formulas. The implemented accelerometer is shown to satisfy the estimated performance parameters with measurements conducted using various test se...
High throughput multi-residue analysis in small volume of complex samples using non depletive equilibrium based SPME approach.
Boyacı, Ezel; Reyes-garcés, Nathaly; Gómez-ríos, G.a.; Pawliszyn, Janusz (2016-07-03)
High efficiency ZVZCS full bridge converter for medium power low input voltage applications
Çetin, Alper; Çadırcı, Işık; Department of Electrical and Electronics Engineering (2000)
Citation Formats
Ö. Sümer Laçin et al., “High Throughput Parylene Micro-Channel Coulter Counter For Parallel Cell Counting and Sorting,” 2014, Accessed: 00, 2021. [Online]. Available: https://hdl.handle.net/11511/86697.