Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Heat Transfer for the Film-Cooled Vane of a 1-1/2 Stage High-Pressure Transonic Turbine-Part I: Experimental Configuration and Data Review With Inlet Temperature Profile Effects
Date
2013-03-01
Author
Kahveci, Harika Senem
MATHISON, RANDALL
DUNN, MICHAEL
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
176
views
0
downloads
Cite This
This paper investigates the vane airfoil and inner endwall heat transfer for a full-scale turbine stage operating at design corrected conditions under the influence of different vane inlet temperature profiles and vane cooling flow rates. The turbine stage is a modern 3D design consisting of a cooled high-pressure vane, an un-cooled high-pressure rotor, and a low-pressure vane. Inlet temperature profiles (uniform, radial, and hot streaks) are created by a passive heat exchanger and can be made circumferentially uniform to within +/- 5% of the bulk average inlet temperature when desired. The high-pressure vane has full cooling coverage on both the airfoil surface and the inner and outer endwalls. Two circuits supply coolant to the vane, and a third circuit supplies coolant to the rotor purge cavity. All of the cooling circuits are independently controlled. Measurements are performed using double-sided heat-flux gauges located at four spans of the vane airfoil surface and throughout the inner endwall region. Analysis of the heat transfer measured for the uncooled downstream blade row has been reported previously. Part I of this paper describes the operating conditions and data reduction techniques utilized in this analysis, including a novel application of a traditional statistical method to assign confidence limits to measurements in the absence of repeat runs. The impact of Stanton number definition is discussed while analyzing inlet temperature profile shape effects. Comparison of the present data (Build 2) to the data obtained for an uncooled vane (Build 1) clearly illustrates the impact of the cooling flow and its relative effects on both the endwall and airfoils. Measurements obtained for the cooled hardware without cooling applied agree well with the solid airfoil for the airfoil pressure surface but not for the suction surface. Differences on the suction surface are due to flow being ingested on the pressure surface and reinjected on the suction surface when coolant is not supplied for Build 2. Part II of the paper continues this discussion by describing the influence of overall cooling level variation and the influence of the vane trailing edge cooling on the vane heat transfer measurements. [DOI: 10.1115/1.4006775]
URI
https://hdl.handle.net/11511/48202
Journal
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME
DOI
https://doi.org/10.1115/1.4006775
Collections
Department of Aerospace Engineering, Article
Suggestions
OpenMETU
Core
Heat Transfer for the Film Cooled Vane of a 1 1 2 Stage High Pressure Transonic Turbine Part I Experimental Configuration and Data Review With Inlet Temperature Profile Effects
Kahveci, Harika Senem; MATHISON, RANDALL; DUNN, MICHAEL (2011-01-01)
This paper investigates the vane airfoil and inner endwall heat transfer for a full-scale turbine stage operating at design corrected conditions under the influence of different vane inlet temperature profiles and vane cooling flow rates. The turbine stage is a modern 3-D design consisting of a cooled high-pressure vane, an un-cooled high-pressure rotor, and a low-pressure vane. Inlet temperature profiles (uniform, radial and hot streaks) are created by a passive heat exchanger and can be made circumferenti...
Heat Transfer for the Film-Cooled Vane of a 1-1/2 Stage High-Pressure Transonic Turbine-Part II: Effect of Cooling Variation on the Vane Airfoil and Inner End Wall
Kahveci, Harika Senem; MATHISON, RANDALL; DUNN, MICHAEL (2013-03-01)
The impact of film cooling on heat transfer is investigated for the high-pressure vane of a 1-1/2 stage high-pressure turbine operating at design corrected conditions. Cooling is supplied through three independently controllable circuits to holes in the inner and outer end wall, vane leading edge showerhead, and the pressure and suction surfaces of the airfoil, in addition to vane trailing edge slots. Four different overall cooling flow rates are investigated and one cooling circuit is varied independently....
Heat Transfer for the Film Cooled Vane of a 1 1 2 Stage High Pressure Transonic Turbine Part II Effect of Cooling Variation on the Vane Airfoil and Inner Endwall
Kahveci, Harika Senem; MATHISON, RANDALL; DUNN, MICHAEL (2011-01-01)
The impact of film cooling on heat transfer is investigated for the high-pressure vane of a one-and-one-half stage high-pressure turbine operating at design corrected conditions. Cooling is supplied through three independently controllable circuits to holes in the inner and outer endwall, vane leading edge showerhead, and the pressure and suction surfaces of the airfoil in addition to vane trailing edge slots. Four different overall cooling flow rates are investigated and one cooling circuit is varied indep...
Heat transfer in ultra-high temperature advanced ceramics under high enthalpy arc-jet conditions
Cecere, Anselmo; Savino, Raffaele; Allouis, Christophe Gerard; Monteverde, Frederic (2015-12-01)
Aim of this work is to analyze the response of an ultra-high temperature ceramic at typical heat flux conditions of thermal protection systems of a re-entry spacecraft. In particular, a ZrB2-SiC based ultra-high temperature advanced ceramic sharp leading edge demonstrator (1 mm nominal radius of curvature) was manufactured and tested in a non-equilibrium high enthalpy supersonic airflow, 20 MJ/kg of peak total enthalpy, by using an arc-jet ground facility. The surface temperature of the leading edge was mon...
Numerical simulation of turbine internal cooling and conjugate heat transfer problems with Rans based turbulance models
Görgülü, İlhan; Akmandor, İbrahim Sinan; Department of Aerospace Engineering (2012)
The present study considers the numerical simulation of the different flow characteristics involved in the conjugate heat transfer analysis of an internally cooled gas turbine blade. Conjugate simulations require full coupling of convective heat transfer in fluid regions to the heat diffusion in solid regions. Therefore, accurate prediction of heat transfer quantities on both external and internal surfaces has the uppermost importance and highly connected with the performance of the employed turbulence mode...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
H. S. Kahveci, R. MATHISON, and M. DUNN, “Heat Transfer for the Film-Cooled Vane of a 1-1/2 Stage High-Pressure Transonic Turbine-Part I: Experimental Configuration and Data Review With Inlet Temperature Profile Effects,”
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME
, pp. 0–0, 2013, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/48202.