Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Magnetic Resonance Imaging in Inhomogeneous Magnetic Fields with Noisy Signal
Date
2008-11-27
Author
Arpinar, V. E.
Eyüboğlu, Behçet Murat
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
232
views
0
downloads
Cite This
In this study, an image reconstruction algorithm for a Magnetic Resonance Imaging (MRI) system with inhomogeneous magnetic fields is proposed. The proposed reconstruction algorithm uses spatial distributions of main magnetic field, Radio Frequency (RF) and gradient fields as inputs, together with the pulse sequence and the noisy Magnetic Resonance (MR) signal. To calculate the noise signal, noise model for MRI with homogeneous fields is extended for inhomogeneous magnetic fields. Using this embedded noise module, different levels of noise signals are generated and added to the MR signal. By using this signal, noise performance of the proposed reconstruction algorithm is evaluated. In order to do that, inputs must be defined. As the main magnetic field input, measured magnetic field outside of a 0.15 T Oxford magnet, which is inhomogeneous, is used. Spin echo pulse sequence with parameters selected for proton density weighted images is used to evaluate the performance of the algorithm. Without noise, relative reconstruction error of the algorithm is 8.5 %. As seen from the simulation results if the noise level increases due to decrease in number of averages or slice thickness, then the relative error increases. Results are obtained for different slice thickness and number of averages. In the worst case, SNR is 18.6 with a relative error of 23 %.
Subject Keywords
Magnetic resonance imaging
,
Inhomogeneous magnetic fields
,
Noise
,
Image reconstruction
,
Tomography
URI
https://hdl.handle.net/11511/55406
Conference Name
4th European Conference of the International Federation for Medical and Biological Engineering (ECIFMBE)
Collections
Department of Electrical and Electronics Engineering, Conference / Seminar
Suggestions
OpenMETU
Core
RF Coil Design for MRI Applications in Inhomogeneous Main Magnetic Fields
Yılmaz, Ayşen; Eyueboglu, B. M. (2006-09-01)
Conventional Magnetic Resonance Imaging (MRI) techniques require homogeneous main magnetic fields. However, MRI applications that are executed in inhomogenous main magnetic fields have been developed in recent years. In this study, RF coil geometries are designed for MRI applications in inhomogeneous magnetic fields. Method of moments is used to obtain the current density distribution on a predefined surface that can produce a desired magnetic field, which is perpendicular to the given inhomogenous main mag...
Magnetic Resonance Electrical Impedance Tomography For Anisotropic Conductivity Imaging
Degirmenci, E.; Eyüboğlu, Behçet Murat (2008-11-27)
Magnetic Resonance Electrical Impedance Tomography (MREIT) brings high resolution imaging of true conductivity distribution to reality. MREIT images are reconstructed based on measurements of current density distribution and a surface potential value, induced by an externally applied current flow. Since biological tissues may be anisotropic, isotropic conductivity assumption, as it is adopted in most of MREIT reconstruction algorithms, introduces reconstruction inaccuracy. In this study, a novel algorithm i...
Magnetic Resonance - Electrical Impedance Tomography (MR-EIT) Research at METU
Eyüboğlu, Behçet Murat (2006-09-01)
Following development of magnetic resonance current density imaging (MRCDI), magnetic resonance - electrical impedance tomography (MR-EIT) has emerged as a promising approach to produce high resolution conductivity images. Electric current applied to a conductor results in a potential field and a magnetic flux density distribution. Using a magnetic resonance imaging (MRI) system, the magnetic flux density distribution can be reconstructed as in MRCDI. The flux density is related to the current density distr...
Electrical impedance tomography using the magnetic field generated by injected currents
Birgul, O; Ider, YZ (1996-11-03)
In 2D EIT imaging, the internal distribution of the injected currents generate a magnetic field in the imaging region which can be measured by magnetic resonance imaging techniques. This magnetic field is perpendicular to the imaging region on the imaging region and it can be used in reconstructing the conductivity distribution inside the imaging region. For this purpose, internal current distribution is found using the finite element method. The magnetic fields due to this current is found using Biot-Savar...
Magnetohydrodynamic Flow Imaging Using Spin-Echo Pulse Sequence
Eroğlu, Hasan Hüseyin; SADIGHI, MEHDI; Eyüboğlu, Behçet Murat (2019-04-24)
In this study, magnetohydrodynamic (MHD) flow of conductive liquids due to injection of electrical current during magnetic resonance imaging (MRI) is investigated. A spin-echo based MRI pulse sequence is proposed to image the MHD flow. Magnetic resonance (MR) phase effects of the MHD flow is related to the MRI pulse parameters and injected current. Average velocity distributions of the MHD flow are reconstructed using the MR phase images. The method is validated by numerical simulations. The reconstruction ...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
V. E. Arpinar and B. M. Eyüboğlu, “Magnetic Resonance Imaging in Inhomogeneous Magnetic Fields with Noisy Signal,” Antwerp, BELGIUM, 2008, vol. 22, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/55406.