Determination of elastic constants of fresh and compact animal bone

Download
1976
Inder, Erk

Suggestions

Determination of the effect of temperature and carbondioxide concentration of the physical properties of Garzan crude oil
Maruta, Şahlu Dembu; Mehmetoğlu, Tanju; Department of Petroleum Engineering (1993)
Determination of flow curves of the metastable austenite
Şimşir, Caner; Davut, Kemal; Gür, Cemil Hakan (null; 2014-09-01)
Thermo-mechanical properties of metastable austenite are significant parameters for the prediction of distortion and residual stresses by heat treatment simulations. Unfortunately, acquisition of thermo-mechanical properties of a metastable phase in the complete process temperature range requires special techniques and instrumentation. in this study, flow curves of metastable austenite of SAE 52100 (EN ıoOCr6) steel were characterized by special compression tests conducted on a deformation dilatometer in 30...
Determination of contact angles of powders by capillaric dewatering of filter cakes
Eratak, Özlem Deniz; Hoşten, Çetin; Department of Mining Engineering (2005)
Solid-liquid contact angle is an important parameter in many particulate processes of the mineral, ceramic and chemical industries. In particular, modification of the contact angle through surface active agents plays a crucial role in froth flotation of minerals. In the case of flat solid surfaces, direct measurement of the contact angle is possible. However, such flat surfaces can not be obtained with finely divided solids typically encountered in flotation applications. Then, indirect methods based on pow...
Determination of the copper losses and thermodynamic of the copper-slag system under magnetite saturation at 1250 °C.
Gün, Bülent; Department of Metallurgical Engineering (1981)
DETERMINATION OF THE BOUNDARY OF AN OBJECT INSERTED INTO A WATER-FILLED CYLINDER
IDER, YZ; NAKIBOGLU, B; Kuzuoğlu, Mustafa; Gençer, Nevzat Güneri (IOP Publishing, 1992-01-01)
In order to circumvent the electrode position determination problem in static electrical impedance tomography, it is possible to insert the object to be imaged into a water-filled cylinder on which the electrodes are at fixed and known positions. It has previously been shown that if the boundary of the internally placed object and the conductivity of the salty water in the cylinder are known, then a significant improvement in the conductivity image of the object is obtained. An algorithm for finding the bou...
Citation Formats