Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Compact Size, and Highly Sensitive, Microwave Sensor for Non-Invasive Measurement of Blood Glucose Level
Date
2021-01-01
Author
Mohammadi, P.
Mohammadia, A.
Demir, Şimşek
KARA, AYŞEN GÜLÇİN
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
278
views
0
downloads
Cite This
None-invasive blood glucose measurement enables effective diagnosis and treatment of diabetic patients. The existing microwave sensors suffer from low sensitivity and large size. This article presents a highly sensitive and compact size non-invasive microwave sensor for real-time blood glucose measurements. We have developed a new sensing technique using directly connected Branch Line Coupler and Split Ring Resonators. This technique significantly improves the sensitivity by mitigating the limited coupling between transmission lines and resonators. In addition, using Split Ring Resonators reduces the sensor size due to capacitive and inductive effects, which are loaded to the Branch Line Coupler. The proposed sensing function is based on shifting the transmission notch frequency in coupled arm of the Branch Line Coupler, which is caused by loading the Split Ring Resonators with varying glucose concentration. A prototype sensor is fabricated and successfully tested using several glucose concentrations in deionized water. Experimental results demonstrate 0.72 MHz/mgdL-1 measurement sensitivity, which is higher in comparison with available sensors in PCB technology. The prototype sensor size is 3.5×3.5×0.16 cm3.
URI
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85105024769&origin=inward
https://hdl.handle.net/11511/90889
Journal
IEEE Sensors Journal
DOI
https://doi.org/10.1109/jsen.2021.3075576
Collections
Department of Electrical and Electronics Engineering, Article
Suggestions
OpenMETU
Core
Nanometer-Thick Mn:NiO and Co:NiO Films for High Performance Nonenzymatic Biosensors
Tunca, Sensu; Tutel, Yusuf; Koylan, Serkan; Ünalan, Hüsnü Emrah (2021-01-01)
People with diabetes require regular blood sugar level monitoring, using commercial enzyme-based biosensors. There is a considerable need to develop biosensors with nonenzymatic electrodes to eliminate the drawbacks of enzymes. Nanostructured nickel oxide (NiO) thin films are highly promising materials for the development of nonenzymatic glucose and hydrogen peroxide (H2O2) biosensors. Although the biosensor performance can be easily attained with nonenzymatic electrodes, their commercialization still requi...
Epidermal growth factor-containing wound closure enhances wound healing in non-diabetic and diabetic rats
Dogan, S.; DEMİRER, SEHER; Kepenekci, I.; Erkek, B.; Kızıltay, Aysel; Hasırcı, Nesrin; MÜFTÜOĞLU, SEVDA FATMA; Nazikoglu, A.; Renda, N.; Dincer, U. D.; ELHAN, ATİLLA HALİL; Kuterdem, E. (2009-04-01)
Background: This study was designed to elucidate the in vivo efficacy of epidermal growth factor (EGF) on wound healing in non diabetic and diabetic rats.
A Novel Artificial Pancreas: Energy Efficient Valveless Piezoelectric Actuated Closed-Loop Insulin Pump for T1DM
Kacar, Alp; Özer, Mehmet Bülent; Tascioglu, Yigit (2020-08-01)
The objective of this work is to develop a closed-loop controlled insulin pump to keep the blood glucose level of Type 1 diabetes mellitus (T1DM) patients in the desired range. In contrast to the existing artificial pancreas systems with syringe pumps, an energy-efficient, valveless piezoelectric pump is designed and simulated with different types of controllers and glucose-insulin models. COMSOL Multiphysics is used for piezoelectric-fluid-structural coupled 3D finite element simulations of the pump. Then,...
Restoring effect of selenium on the molecular content, structure and fluidity of diabetic rat kidney brush border cell membrane
Gurbanov, Rafig; Bilgin, Mehmet; Severcan, Feride (Elsevier BV, 2016-04-01)
Diabetic kidney disease (DKD) is a dominant factor standing for kidney impairments during diabetes. In this study, attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy was used to disclose the diabetes-induced structural changes in the kidney and evaluate the effects of selenium on diabetes. The increase in the area of the olefinic band indicated increased amount of lipid peroxidation end products in diabetic kidney brush border cell membrane. Moreover, saturated lipid content of ...
Diabetes induces compositional, structural and functional alterations on rat skeletal soleus muscle revealed by FTIR spectroscopy: a comparative study with EDL muscle
Bozkurt, Ozlem; Severcan, Mete; Severcan, Feride (2010-01-01)
Diabetes Mellitus (DM) is a metabolic disorder, characterized by abnormally high blood glucose levels due to decreased secretion or effectiveness in function of insulin. Having a role in carbohydrate and lipid metabolism, skeletal muscle is affected by the absence of insulin in diabetic conditions. This current study reports the application of Fourier transform infrared (FTIR) spectroscopy in the determination of macromolecular alterations in streptozotocin (STZ)-induced diabetic rat skeletal Soleus (SOL) m...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
P. Mohammadi, A. Mohammadia, Ş. Demir, and A. G. KARA, “Compact Size, and Highly Sensitive, Microwave Sensor for Non-Invasive Measurement of Blood Glucose Level,”
IEEE Sensors Journal
, pp. 0–0, 2021, Accessed: 00, 2021. [Online]. Available: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85105024769&origin=inward.