Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Nanometer-Thick Mn:NiO and Co:NiO Films for High Performance Nonenzymatic Biosensors
Date
2021-01-01
Author
Tunca, Sensu
Tutel, Yusuf
Koylan, Serkan
Ünalan, Hüsnü Emrah
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
234
views
0
downloads
Cite This
People with diabetes require regular blood sugar level monitoring, using commercial enzyme-based biosensors. There is a considerable need to develop biosensors with nonenzymatic electrodes to eliminate the drawbacks of enzymes. Nanostructured nickel oxide (NiO) thin films are highly promising materials for the development of nonenzymatic glucose and hydrogen peroxide (H2O2) biosensors. Although the biosensor performance can be easily attained with nonenzymatic electrodes, their commercialization still requires development of cost-effective and mass-production methods. In this work, we demonstrate the use of ultrasonic spray deposited, nanometer-thick, manganese and cobalt doped NiO (Mn:NiO and Co:NiO) films on indium tin oxide (ITO) coated glass substrates for glucose sensing. Sensor characterization followed detailed materials characterization. Nanometer-thick Co:NiO film electrodes showed better glucose sensor performance than those of bare NiO and Mn:NiO electrodes. High sensitivity of 1.67 μA/μM·cm2, a low detection limit of 231 nM, and a fast response time of 5.4 s within the linear range of 16-308 μM were obtained from nanometer-thick Co:NiO film electrodes. Amperometric measurements showed significant electrode reproducibility and stability. Nanometer-thick Co:NiO film electrode was also used to demonstrate actual clinical glucose measurements using human blood serum as a glucose source. Moreover, all fabricated nanometer-thick film electrodes were also utilized as H2O2 sensors. This work provides a novel approach for monitoring the biosensor performance using nanometer-thick doped NiO film electrodes. Obtained results demonstrated the potential of ultrasonic spray deposition method for the mass-production of high-performance nonenzymatic nanometer-thick film biosensors.
Subject Keywords
doped nickel oxide
,
glucose sensor
,
hydrogen peroxide sensor
,
thin film electrodes
,
ultrasonic spray deposition
URI
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85120306644&origin=inward
https://hdl.handle.net/11511/95025
Journal
ACS Applied Nano Materials
DOI
https://doi.org/10.1021/acsanm.1c03221
Collections
Department of Metallurgical and Materials Engineering, Article
Suggestions
OpenMETU
Core
Compact Size, and Highly Sensitive, Microwave Sensor for Non-Invasive Measurement of Blood Glucose Level
Mohammadi, P.; Mohammadia, A.; Demir, Şimşek; KARA, AYŞEN GÜLÇİN (2021-01-01)
None-invasive blood glucose measurement enables effective diagnosis and treatment of diabetic patients. The existing microwave sensors suffer from low sensitivity and large size. This article presents a highly sensitive and compact size non-invasive microwave sensor for real-time blood glucose measurements. We have developed a new sensing technique using directly connected Branch Line Coupler and Split Ring Resonators. This technique significantly improves the sensitivity by mitigating the limited coupling ...
Curcumin ameliorates impaired insulin/IGF signalling and memory deficit in a streptozotocin-treated rat model
IŞIK, AHMET TURAN; Celik, Turgay; Ulusoy, Gokhan; Ongoru, Onder; Elibol, Birsen; Doruk, Huseyin; Bozoglu, Ergun; Kayir, Hakan; Mas, Mehmet Refik; Akman, Serif (Springer Science and Business Media LLC, 2009-03-01)
Increased serum insulin levels and reduced peripheral insulin activities seen in insulin resistance syndrome are associated with age-dependent cognitive impairment and Sporadic Alzheimer's Disease (SAD), suggesting a disturbance in the insulin signalling system in the brain and possibly being one of the causes of dementia. Therefore, the streptozotocin (STZ)-induced animal may be an appropriate model for the investigation of SAD and related dementia. This study was designed to investigate the beneficial eff...
Epidermal growth factor-containing wound closure enhances wound healing in non-diabetic and diabetic rats
Dogan, S.; DEMİRER, SEHER; Kepenekci, I.; Erkek, B.; Kızıltay, Aysel; Hasırcı, Nesrin; MÜFTÜOĞLU, SEVDA FATMA; Nazikoglu, A.; Renda, N.; Dincer, U. D.; ELHAN, ATİLLA HALİL; Kuterdem, E. (2009-04-01)
Background: This study was designed to elucidate the in vivo efficacy of epidermal growth factor (EGF) on wound healing in non diabetic and diabetic rats.
A Novel Artificial Pancreas: Energy Efficient Valveless Piezoelectric Actuated Closed-Loop Insulin Pump for T1DM
Kacar, Alp; Özer, Mehmet Bülent; Tascioglu, Yigit (2020-08-01)
The objective of this work is to develop a closed-loop controlled insulin pump to keep the blood glucose level of Type 1 diabetes mellitus (T1DM) patients in the desired range. In contrast to the existing artificial pancreas systems with syringe pumps, an energy-efficient, valveless piezoelectric pump is designed and simulated with different types of controllers and glucose-insulin models. COMSOL Multiphysics is used for piezoelectric-fluid-structural coupled 3D finite element simulations of the pump. Then,...
Validity and reliability of time management questionnaire
ALAY, SEMA; Koçak, Mehmet Settar (SAGE Publications, 2002-01-01)
the purpose of this study was to test the psychometric properties of the 49-item Diabetes Time Management Questionnaire (DTMQ) in individuals with diabetes. The (DTMQ) was designed to assess general time management skills and those specifically relevant to compliance to a diabetes healthcare regimen.
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
S. Tunca, Y. Tutel, S. Koylan, and H. E. Ünalan, “Nanometer-Thick Mn:NiO and Co:NiO Films for High Performance Nonenzymatic Biosensors,”
ACS Applied Nano Materials
, pp. 0–0, 2021, Accessed: 00, 2021. [Online]. Available: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85120306644&origin=inward.