Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Realization of virtual fluid environment on a robotic gait trainer for therapeutic purposes
Download
index.pdf
Date
2017
Author
Ertop, Tayfun Efe
Metadata
Show full item record
Item Usage Stats
231
views
119
downloads
Cite This
Patients with disorders such as spinal cord injury, cerebral palsy and stroke can perform full gait when assisted, which progressively helps them regain the ability to walk. A very common way to create assistive effects is aquatic therapy. Aquatic environment also creates resistive effects desired for increasing muscle activity. Simulating the fluid environment using a robotic system would enable therapists to adjust various fluid parameters so that the therapy is tailored to each patient’s unique state. In this study, realization of a virtual fluid environment on a robotic gait trainer for rehabilitation purposes is presented. A model is created to determine torques and forces exerted on a partially submerged human body by the fluid environment. Then, the fluid model is used to create a control scheme which is implemented on a robotic gait trainer. A compensation algorithm is developed so that weight and friction of robotic links are countered. Smooth transition between stance and swing phases of gait is ensured with a developed algorithm that only uses kinematic data. Experiments with healthy subjects were done to verify the stance-swing algorithm, the changes in gait characteristics between land and water conditions, and to assess effects of changes in fluid model parameters to gait characteristics. It is shown that realization of virtual fluid environment on robotic gait trainer is achieved. The torque measurements showed that the controller was able to make the orthosis transparent to the patient. Significant changes in gait characteristic were observed by modifying fluid model parameters.
Subject Keywords
Gait disorders.
,
Movement disorders.
,
Robotics in medicine.
,
Medical rehabilitation.
URI
http://etd.lib.metu.edu.tr/upload/12621016/index.pdf
https://hdl.handle.net/11511/26474
Collections
Graduate School of Natural and Applied Sciences, Thesis
Suggestions
OpenMETU
Core
Realization of human gait in virtual fluid environment on a robotic gait trainer for therapeutic purposes
Ertop, Tayfun Efe; Yuksel, Tolga; Konukseven, Erhan İlhan (Elsevier BV, 2018-7)
Patients with disorders such as spinal cord injury, cerebral palsy and stroke can perform full gait when assisted, which progressively helps them regain the ability to walk. A very common way to create assistive effects is aquatic therapy. Aquatic environment also creates resistive effects desired for strength building. In this study, realization of a virtual fluid environment on a robotic gait trainer is presented as an alternative method. A model was created to determine torques and forces acting on the h...
Tissue Engineered, Guided Nerve Tube Consisting of Aligned Neural Stem Cells and Astrocytes
Yucel, Deniz; Kose, Gamze Torun; Hasırcı, Vasıf Nejat (2010-12-01)
Injury of the nervous system, particularly in the spinal cord, impairs the quality of life of the patient by resulting in permanent loss of neurologic function. The main limitation in spinal cord regeneration is the lack of extracellular matrix to guide nerves for functional recovery of the transected nerve tissue. In the present study, a tissue engineered nerve tube was prepared by wrapping neural stem cells (NSCs) on aligned fibers using a micropatterned film with astrocytes aligned along the microgrooves...
Construction of a PLGA based, targeted siRNA delivery system for treatment of osteoporosis
Bilecen, Deniz Sezlev; Carlos Rodriguez-Cabello, Jose; Uludag, Hasan; Hasırcı, Vasıf Nejat (2017-01-01)
Osteoporosis, a systemic skeletal disorder, occurs when bone turnover balance is disrupted. With the identification of the genes involved in the pathogenesis of the disease, studies on development of new treatments has intensified. Shortinterfering RNA (siRNA)is used to knockdown disease related gene expressions. Targeting siRNA in vivo is challenging. The maintenance of therapeutic plasma level is hampered by clearance of siRNA from the body. Targeted systems are useful in increasing the drug concentration...
Improvement of bioactivity with dual bioceramic incorporation to nanofibrous PCL scaffolds
Altunordu, Gercem; Tezcaner, Ayşen; Evis, Zafer; Keskin, Dilek (2023-03-01)
Bone tissue injuries, diseases or related clinical interventions require bone tissue engineering (BTE) approaches for regeneration of large bone defects, especially for compromised situations. Most BTE applications in literature focused on composites of polymers with a single type of bioceramic. However, native bone matrix has various inorganic components. Accordingly, this study aimed to investigate the use of dual bioceramics in BTE scaffolds prepared by wet-electrospinning of Poly-caprolactone (PCL) and ...
Estimation of Ground Reaction Forces Using Low-Cost Instrumented Forearm Crutches
Seylan, Çağlar; Saranlı, Uluç (2018-06-01)
Instrumented crutches are useful for many rehabilitation tasks, including monitoring the correctness of crutch use, analyzing gait properties for patients with lower-limb impairments, as well as providing sensory data for controlling lower-body robotic orthoses. In this paper, we describe the design and analysis of an instrumented crutch system equipped with low-cost accelerometer and pressure sensors to estimate all components of the ground reaction force (GRF), providing a well-defined and physically mean...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
T. E. Ertop, “Realization of virtual fluid environment on a robotic gait trainer for therapeutic purposes,” M.S. - Master of Science, Middle East Technical University, 2017.