Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Antimicrobial performance of mesoporous titania thin films: role of pore size, hydrophobicity, and antibiotic release
Download
10.2147:IJN.S95375.pdf
Date
2016-01-01
Author
Atefyekta, Saba
Ercan, Batur
Karlsson, Johan
Taylor, Erik
Chung, Stanley
Webster, Thomas J.
Andersson, Martin
Metadata
Show full item record
This work is licensed under a
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
.
Item Usage Stats
147
views
108
downloads
Cite This
Implant-associated infections are undesirable complications that might arise after implant surgery. If the infection is not prevented, it can lead to tremendous cost, trauma, and even life threatening conditions for the patient. Development of an implant coating loaded with antimicrobial substances would be an effective way to improve the success rate of implants. In this study, the in vitro efficacy of mesoporous titania thin films used as a novel antimicrobial release coating was evaluated. Mesoporous titania thin films with pore diameters of 4, 6, and 7 nm were synthesized using the evaporation-induced self-assembly method. The films were characterized and loaded with antimicrobial agents, including vancomycin, gentamicin, and daptomycin. Staphylococcus aureus and Pseudomonas aeruginosa were used to evaluate their effectiveness toward inhibiting bacterial colonization. Drug loading and delivery were studied using a quartz crystal microbalance with dissipation monitoring, which showed successful loading and release of the antibiotics from the surfaces. Results from counting bacterial colony-forming units showed reduced bacterial adhesion on the drug-loaded films. Interestingly, the presence of the pores alone had a desired effect on bacterial colonization, which can be attributed to the documented nanotopographical effect. In summary, this study provides significant promise for the use of mesoporous titania thin films for reducing implant infections.
Subject Keywords
Mesoporous titania
,
Antibacterial
,
Drug delivery
,
Implant coating
URI
https://hdl.handle.net/11511/34677
Journal
INTERNATIONAL JOURNAL OF NANOMEDICINE
DOI
https://doi.org/10.2147/ijn.s95375
Collections
Department of Metallurgical and Materials Engineering, Article
Suggestions
OpenMETU
Core
Immobilization of heparin on chitosan-grafted polyurethane films to enhance anti-adhesive and antibacterial properties
Kara, Filiz; AKSOY, EDA AYŞE; ÇALAMAK, SEMİH; Hasırcı, Nesrin; AKSOY, SERPİL (2016-01-01)
Infections caused by bacteria adhering to implant surfaces are one of the main reasons for the failure of the implants. In this study, polyurethane (PU), which is the most commonly used polymer in the production of medical devices, was synthesized and surfaces of polyurethane films were modified by chitosan (CH) grafting and heparin (Hep) immobilization in order to enhance anti-adhesiveness and antibacterial properties. Functional groups present on the surface, topographical shapes, and free energies of the...
Anodized Tantalum Surfaces for Orthopedic Applications
Uslu, Ece; Ercan, Batur (null; 2018-04-30)
Currently used implant materials do not suffice the needs of patients mainly due to their poor osseointegration with the juxtaposed bone tissue, which ultimately leads to failure of the implant. To overcome this issue, better orthopedic implants exhibiting bioactive characteristics are required. Tantalum is a good candidate as a new generation orthopedic implant materials due to its superior mechanical and chemical properties compared to the currently-used metallic implant materials. However, its bioinert n...
Reduced adhesion of macrophages on anodized titanium with select nanotube surface features
Rajyalakshmi, Amancherla; Ercan, Batur; Balasubramanian, K.; Webster, Thomas J. (2011-01-01)
One of the important prerequisites for a successful orthopedic implant apart from being osteoconductive is the elicitation of a favorable immune response that does not lead to the rejection of the implant by the host tissue. Anodization is one of the simplest surface modification processes used to create nanotextured and nanotubular features on metal oxides which has been shown to improve bone formation. Anodization of titanium (Ti) leads to the formation of TiO(2) nanotubes on the surface, and the presence...
Antibacterial Nanostructured Polyhydroxybutyrate Membranes for Guided Bone Regeneration
Karahaliloglu, Zeynep; Ercan, Batur; Taylor, Erik N.; Chung, Stanley; DENKBAŞ, EMİR BAKİ; Webster, Thomas J. (2015-12-01)
The principle of guided bone regeneration (GBR) in orthopedic, cranio-maxillofacial and dental tissue engineering applications is to create a secluded space for the treatment of large bone defects while excluding fibrous connective tissue formation at the defect area. In dental surgeries, a GBR membrane is placed near the dental implant in post-extraction sockets to grow new bone at the implant site, along with inhibiting infection due to the microbial nature of the mouth flora. Poly[(R)-3-hydroxybutyric ac...
Additive manufacturing of biodegradable magnesium implants and scaffolds: Review of the recent advances and research trends
Sezer, Nurettin; Evis, Zafer; Koc, Muammer (2021-03-01)
Synthetic grafting needs improvements to eliminate secondary surgeries for the removal of implants after healing of the defected tissues. Tissue scaffolds are engineered to serve as temporary templates, which support the affected tissue and gradually degrade through the healing period. Beside mechanical function to withstand the anatomic loading conditions, scaffolds should also provide a decent biological function for the diffusion of nutrients and oxygen to the cells, and excretion of the wastes from the ...
Citation Formats
IEEE
ACM
APA
CHICAGO
MLA
BibTeX
S. Atefyekta et al., “Antimicrobial performance of mesoporous titania thin films: role of pore size, hydrophobicity, and antibiotic release,”
INTERNATIONAL JOURNAL OF NANOMEDICINE
, pp. 977–990, 2016, Accessed: 00, 2020. [Online]. Available: https://hdl.handle.net/11511/34677.