Show/Hide Menu
Hide/Show Apps
Logout
Türkçe
Türkçe
Search
Search
Login
Login
OpenMETU
OpenMETU
About
About
Open Science Policy
Open Science Policy
Open Access Guideline
Open Access Guideline
Postgraduate Thesis Guideline
Postgraduate Thesis Guideline
Communities & Collections
Communities & Collections
Help
Help
Frequently Asked Questions
Frequently Asked Questions
Guides
Guides
Thesis submission
Thesis submission
MS without thesis term project submission
MS without thesis term project submission
Publication submission with DOI
Publication submission with DOI
Publication submission
Publication submission
Supporting Information
Supporting Information
General Information
General Information
Copyright, Embargo and License
Copyright, Embargo and License
Contact us
Contact us
Design and implementation of advanced pulse width modulation techniques and passive filters for voltage source inverter driven three-phase ac motors
Download
index.pdf
Date
2010
Author
Nebi, Onur Çetin
Metadata
Show full item record
Item Usage Stats
315
views
173
downloads
Cite This
Advanced pulse width modulation (PWM) techniques such as space vector PWM, active zero state PWM, discontinuous PWM, and near state PWM methods are used in three-phase AC motor drives for the purpose of obtaining low PWM current ripple, wide voltage linearity range, and reduced common mode voltage (CMV). In some applications, a filter is inserted between the inverter and the motor for the purpose of reducing the stresses in the motor. The motor current PWM ripple components, terminal voltage overshoots, shaft voltage, and bearing currents, etc. can all be reduced by means of PWM techniques and passive filters. Various PWM techniques and passive filter types exist. This thesis studies the combinations of PWM techniques and filters and evaluates the performance of the motor drive in terms of the discussed stresses in the motor. PWM techniques are reviewed, a generalized algorithm for the implementation of PWM techniques is developed, and implementation on a 4 kW rated drive is demonstrated. Filter types are studied, among them the common mode inductor and the pure sine filter (PSF) configurations are investigated in detail. Filters are designed and their laboratory performance is evaluated. In the final stage the advanced PWM techniques and filters are combined, the incompatibility problem of discontinuous PWM methods with the PSF is illustrated. A cure based on rate of change limiter is proposed and its feasibility proven in the laboratory experiments. With the use of the proposed PWM algorithm and PSF, a motor drive with ideal DC to AC conversion stage (DC to pure sine) is achieved and its performance is demonstrated in the laboratory.
Subject Keywords
Applications of electric power.
URI
http://etd.lib.metu.edu.tr/upload/12612236/index.pdf
https://hdl.handle.net/11511/19797
Collections
Graduate School of Natural and Applied Sciences, Thesis
Suggestions
OpenMETU
Core
Series active filter design, control, and implementation with a novel load voltage harmonic extraction method
Şentürk, Osman Selçuk; Hava, Ahmet Masum; Department of Electrical and Electronics Engineering (2007)
Series Active Filters (SAF) are designed for harmonic isolation and load voltage regulation of single-phase and three-phase voltage harmonic source type nonlinear loads. The novel Absolute Value Method (AVM) for load voltage harmonic extraction is proposed and applied in the control algorithm of SAF. The SAF compensated systems are represented by simplified linear models such that SAF controller gains can be easily determined. Harmonic isolation and load voltage regulation performances of 2.5 kW single-phas...
Optimizing transient and filtering performance of a C-type 2nd harmonic power filter by the use of solid-state switches
Gerçek, Cem Özgür; Ertaş, Arif; Department of Electrical and Electronics Engineering (2007)
In this research work, the performance of a C-type, 2nd harmonic power filter is optimized by the use of a thyristor switched damping resistor. In the design of conventional C-type, 2nd harmonic filters; the resistance of permanently connected damping resistor is to be optimized for minimization of voltage stresses on filter elements arising from switchings in transient state and for maximization of filtering effectiveness in the steady-state. Transformer inrush current during energization of power transfor...
Output voltage control of a four-leg inverter based three-phase ups by means of stationary frame resonant filter banks
Demirkutlu, Eyyüp; Hava, Ahmet Masum; Department of Electrical and Electronics Engineering (2006)
A method for high performance output voltage control of a four-leg inverter based three-phase transformerless UPS is proposed. Voltage control loop is employed and the method employs stationary frame resonant filter controllers for the fundamental and harmonic frequency components. A capacitor current feedback loop provides active damping and enhances the output voltage dynamic performance. The controller design and implementation details are given. Linear and nonlinear loads for balanced and unbalanced loa...
Design and implementation of a voltage source converter based hybrid active power filter
Uçak, Onur; Ermiş, Muammer; Department of Electrical and Electronics Engineering (2009)
This research work is devoted to the analysis, design and implementation of a shunt connected Hybrid Active Power Filter by the use of a lower rated voltage source PWM converter, and a series connected LC passive filter. In recent years, voltage and current harmonics have become a serious problem both in transmission and distribution systems, due to the widespread usage of non-linear loads such as diode/thyristor rectifiers, electric arc furnaces and motor drives. In order to obtain a better performance tha...
Repetitive control of a three-phase uninterruptible power supply with isolation transformer
Çetinkaya, Süleyman; Hava, Ahmet Masum; Department of Electrical and Electronics Engineering (2006)
A repetitive control method for output voltage control of a three phase uninterruptible power supply (UPS) with isolation transformer is investigated. In the method voltage control loop is employed in the stationary dq frame. The controller eliminates the periodic errors on the output voltages due to inverter voltage nonlinearity and load disturbances. The controller design and implementation details are given. The controller is implemented on a 5-kVA UPS prototype which is constructed in laboratory. Linear...